My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 1998 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2019 3:46:44 AM
Creation date
8/8/2019 2:04:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998 - 2004
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
242
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDLW TANK INFORMATION AN EST RESULTS <br /> l <br /> &F-P,723nkno%gy <br /> 8900 SHOAL CREEK, BUILDING 200 <br /> TEST DATE: 07/17/03 AUSTIN,TEXAS 78757(512)451-6334 WORK ORDER NUMBER: 2227624 <br /> CLIENT: 7-ELEVEN, INC. SITE: 7-ELEVEN # 19976 MKT <br /> Tank ID: #2 3 Tank manifolded: NO Bottom to top fill in inches: 143.0 <br /> Product: PREMIUM Vent manifolded: NO Bottom to grade in inches: 150.0 <br /> Capacity in gallons: 9,684 Vapor recovery manifolded: yEs Fill pipe length in inches: 53.2 <br /> Diameter in inches: 90.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 356 Overspill protection: yEs Stage I vapor recovery: DUAL <br /> Material: DW FIBERG Installed: ATG Stage II vapor recovery: BALANCE <br /> CP installed on: <br /> COMMENTS <br /> TANKT <br /> 5 <br /> £S t1 {? <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: RED JA=T <br /> Fluid volume in gallons: Model: Fx1V <br /> Tank water level in inches: S/N: unreadable <br /> Test time: Open time in sec: 4.00 <br /> Number of thermisters: NOT <br /> TESTED Holding psi: 24 NOT <br /> Specific gravity: Resiliency cc: 140 TESTED <br /> Water table depth in inches: Test leak rate ml/m: 189.0 <br /> Determined by(method): Metering psi: 10 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS <br /> COMMENTS COMMENTS <br /> 171ATE`rTRb`1 . S :IS/# EE1Er2 ` #'fi pk? "� <br /> . .. <br /> LINE A :' <br /> Test time: <br /> Ullage volume: Material: ENVIRON <br /> Ullage pressure: Diameter(in): 1.5 <br /> Results: Length (ft): 40.0 <br /> Test psi: 50 <br /> DATA FOR UTS-4T ONLY: Bleedback cc: 0 <br /> Time of test 1: Test time (min): 60 <br /> Temperature: NOT Start time: 16:34 NOT NOT NOT <br /> Flow rate (cfh): TESTED End time: 17:34 TESTED TESTED TESTED <br /> Time of test 2: Final gph: 0.000 <br /> Temperature: Result: PASS <br /> Flow rate (cfh): Pump type: PRESSURE <br /> Time of test 3: Pump make: FE PETRO <br /> Temperature: <br /> Flow rate (cfh): Impact Valves Operational: yES <br /> COMMENTS COMMENTS <br /> Printed 07/23/2003 12:06 SBOWERS <br />