My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
INSTALL 2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2019 4:39:40 AM
Creation date
8/8/2019 2:05:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2003
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
~ ble Entry <br /> Positive Seal Quality Materials <br /> Corrosion Resistance <br /> sump Entry The exterior studded metal <br /> Flexible entry boots have been compression ring that provides <br /> tested to withstand a minimum the positive sealing pressure is <br /> of 6' of liquid head pressure. encapsulated within rubber to <br /> These seals provide a studded protect it from corrosion. More <br /> flange connection to create a than a 1/8"of rubber isolates the <br /> positive and secure seal where metallic studded ring from the <br /> the rubber contacts the sump ground environment. All studs <br /> wall and also around the pipe or are made of 401 stainless steel <br /> conduit. Tightening down on a and are only exposed on the <br /> series of stud fasteners with a inside of the containment sump. <br /> compression ring provides a <br /> high compression mechanical <br /> seal compared to screw on type Chemical Compatibility <br /> bulkhead seals. All seals are made of specially <br /> formulated Buna-N rubber <br /> compound which has been <br /> Angled Entries independently tested to insure its <br /> Pipe and conduit entering compatibility with a wide <br /> the containment sumps may assortment of chemicals. These <br /> not be perpendicular with tests include measuring the <br /> the sump wall. Angled entries material's retention of properties ` <br /> are generally a result of as well as the physical <br /> directional plumbing restrictions characteristics of the seal after <br /> on the inside of the exposure. <br /> containment chamber due to <br /> space limitations. Flexible entry UL/ Listed <br /> boots are flexible enough to <br /> angled pipe or conduit Environ flexible entry boots are Listed with Underwriters <br /> permit tries an two axises) into the Laboratories, Inc., (UL). The scope of the tests include broad <br /> en <br /> si tries ( of a containment compatibility testing for both petroleum products and burial <br /> environments as well as physical testing to confirm the entry boots <br /> chamber. All flexible entry structural integrity and liquid tightness. <br /> boots permit angled entries up <br /> to a 15 degree angle off the Sizes Available <br /> perpendicular center line in any Application <br /> direction without leaking or �. i ��,. > <br /> putting undue stress on the pipe �•`� � <br /> or conduit seal. i � _ to,wal3l91 ngK <br /> 9,,, <br /> Designed to seal1.051 <br /> 3/4'.tigid NcoL:.�«y <br /> Universal Alignment <br /> 1.32" 3100 Designed to sea{1 rigid conduit. <br /> These seals are also capable of �. _. <br /> universal pipe alignment either4.25" FEB-3150 Des9 <br /> µ ned to seal 1-1/2'standard rigid PIPs. <br /> up and down or side to side. Thisfle�obie pipe <br /> feature allows accommodation of ,� 1.81" 4.75" FEB-5150 Designed to seal 1-1R"Gwaax <br /> 6:25' FEB-6150 Designed to seal1-1/2"GsoAexflexiblepim <br /> pipe entry holes which are 1.81" <br /> installed slightly off exact center G --7 2,37, 625• FEB-5200 Designed to seal 2"GeoRaKfle)dblepipe. <br /> alignment in the chamber wall. Designed to seal 3"standard rigid pipe. <br /> This movement will prevent the \ _-� 3.50" 6.25" FEB g <br /> chamber wall from putting C 3.50" 6.25" `FEB-6350 Designed to seal 3'rigid ducting. <br /> undue stress on the pipe <br /> coupling/fitting joint and the <br /> 3.90" 7.75" FEB 7390 Designed to seal 3-1/2"custom pipe. <br /> entry boot as well. For flexible t f ': 4.50" 7.75" FEB-7400 Designed to seal 4"standard rigid pipe. <br /> piping applications within <br /> dispenser sumps, the stresses 4.50" 7.75" `FEB-7450 Designed to seal 4"GeoDuctfle>uble ducting. <br /> 9 FEB-8600 Designed to seal 6"standard rigid pipe. <br /> on the pipe fittings below the 6.50" <br /> product inlets are minimized by <br /> •ThesenoorsreauireaSun Reaucer0onrnsdaseoaraterv.ornncruaeanavum <br /> emauowrorauP'°mirie Msm° <br /> the boot's flexibility. <br /> ■ <br /> Patent claims allowed. ����r�n <br /> EP;0090 620 Pennsylvania Drive•Exton,PA 19341 •Tel:(610)321-0200•customer Service 18001 833-1883 a y � < <br /> J.,,,r99x,5Mr.G Fax:16101 321.0406•http://www.envproduct.com•U.S.Patent 5263794.527151859199�67 5366318. <br /> 5346625,5398976,Other U.S.and Worldwide Patents Pending•m Copyright <br />
The URL can be used to link to this page
Your browser does not support the video tag.