• Thirty -Year Warranty' - With <br />over 30 years proven performance <br />in the marketplace, UL/ULC Listed <br />RED THREAD IIA pipe, fittings and <br />adhesive carry a 30 -year warranty. <br />The product is warranted to be <br />free from defects in material and <br />workmanship -and against internal <br />and external corrosion -when used <br />for underground transportation of <br />fuels. <br />• Outstanding Corrosion <br />Resistance - UL/ULC Listed RED <br />THREAD IIA pipe resists internal <br />and external corrosion from <br />hazardous soils, fuels and other <br />corrosive fluids. The internal and <br />external corrosion is verified by full <br />immersion testing (I.D. and O.D.) <br />of the fiberglass systems. Full <br />immersion testing is not required <br />by UL 971 for flexible systems. In <br />addition, RED THREAD IIA <br />fiberglass pipe is not affected by <br />microbial attack. <br />• Exceptional Flow <br />Characteristics - RED THREAD IIA <br />pipe has the largest I.D. in the <br />fueling industry -allowing <br />you to sell <br />twice the <br />fuel per <br />foot than <br />2.235" any 1'f" <br />fI D --.- flexible <br />product <br />on the <br />market. <br />What that <br />means to you is <br />that you can get twice the flow in <br />a 2" RED THREAD IIA product <br />versus an 11h" flexible product. <br />Three-inch RED THREAD IIA <br />fiberglass pipe has a nominal <br />3.360" I.D.—much larger than 3" <br />flexible systems. Fiberglass fittings <br />create minimal pressure loss, <br />unlike most flexible fittings. <br />- Quality Assurance - RED <br />THREAD IIA fiberglass piping <br />undergoes constant testing to <br />meet the high quality standards <br />established by Smith Fibercast. <br />These quality assurance procedures <br />exceed the minimum test <br />requirements of Underwriters <br />Laboratories. All UL/ULC Listed <br />RED THREAD IIA molded fittings <br />are 100 percent hydrostatically <br />tested per UL/ULC requirements. <br />Also, Smith Fibercast 100% <br />prooftests all piping, which exceeds <br />UL requirements. Secondary <br />containment fittings are also <br />tested in accordance with <br />standards approved by UL/ULC. <br />• Permeability - RED THREAD IIA <br />primary piping exceeds current UL <br />allowable permeability by 95%. <br />UL 971 allows 4 grams/m2/day for <br />primary piping. That amount <br />correlates to 0.16 gallons per 100 <br />feet in 30 days in a 2 -inch I.D. <br />primary pipe. RED THREAD IIA <br />secondary containment piping <br />exceeds the current UL allowable <br />permeability by 99.2%. The <br />allowable permeability by UL <br />971 for secondary piping is 24 <br />grams/m2/day. That amount <br />correlates to 1.0+ gallons per 200 <br />feet in 30 days in a -2-inch I.D. <br />secondary pipe. <br />• Easy -to -Install Containment <br />Fittings - Female threaded inserts <br />are factory installed in one-half of <br />the two-piece containment <br />fitting. Companion bolts are <br />shipped with each fitting. Simply <br />apply adhesive, drop the bolt in, <br />tighten... and the joint is <br />complete. <br />Please review Smith Fibercast's written warranty to determine the terms and conditions. <br />