BILLING PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
BILLING PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 11:56:49 AM
Creation date
8/8/2019 4:19:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
136
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"NIFIED PROGRAM CONSOLIDATED F <br />TANK <br />UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br />VI. PIPING CONSTRUCTION (Check all that apply) Page _ of <br />UNDERGROUND PIPING <br />ABOVEGROUND PIPING <br />SYSTEM TYPE ®1. PRESSURE [12. SUCTION ❑ 3. GRAVITY 458 <br />❑ 1. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY 459 <br />CONSTRUCTION / ❑ 1. SINGLE WALL ❑ 3. LINED TRENCH ❑ 99. OTHER 460 <br />❑ 1. SINGLE WALL ❑ 95. UNKNOWN 462 <br />MANUFACTURER ® 2. DOUBLE WALL ❑ 95. UNKNOWN <br />❑ 2. DOUBLE WALL ❑ 99. OTHER <br />MANUFACTUREREnviron 461 <br />MANUFACTURER 463 <br />❑ 1. BARE STEEL ❑OMPATIBLE w/10096 METHANOL <br />❑ 1. BARE STEEL [16. FRP COMPATIBLE W/100°h METHANOL <br />❑ 2. STAINLESS STEEL [17. GALVANIZED STEEL ❑ UKNOWN <br />❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br />❑ 3. PLASTIC COMPATIBLE W/ CONTENTS ❑ 99. OTHER <br />❑ 3. PLASTIC COMPATIBLE W/ CONTENTS ❑ 8. FLEXIBLE (HDPE) ❑ 99. OTHER <br />® 4. FIBERGLASS ® 8. FLEXIBLE (HDPE) <br />❑ 4. FIBERGLASS ❑ 9. CATHODIC PROTECTION <br />❑ 5. STEEL W/COATING ❑ 9. CATHODIC PROTECTION 464 <br />❑ 5. STEEL W/COATING ❑ 95. UNKNOWN 465 <br />VII. PIPING LEAK DETECTION (Check all that apply) (A description of the monitoring program shall be submitted to the local agency.) <br />UNDERGROUND PIPING ABOVEGROUND PIPING <br />SINGLE WALL PIPING 466 <br />SINGLE WALL PIPING 467 <br />PRESSURIZED PIPING (Check all that apply): <br />PRESSURIZED PIPING (Check all that apply): <br />❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR <br />❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR <br />LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION +AUDIBLE AND VISUAL <br />LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION + AUDIBLE AND VISUAL <br />ALARMS. <br />ALARMS. <br />❑ 2. MONTHLY 0.2 GPH TEST <br />❑ 2. MONTHLY 0.2 GPH TEST <br />❑ 3. ANNUAL INTEGRITY TEST (0.1GPH) <br />❑ 3. ANNUAL INTEGRITY TEST (0.1GPH) <br />❑ 4. DAILY VISUAL CHECK <br />CONVENTIONAL SUCTION SYSTEMS <br />CONVENTIONAL SUCTION SYSTEMS (Check all that apply) <br />115. DAILY VISUAL MONITORING OF PUMPING SYSTEM +TRIENNIAL PIPING INTEGRITY <br />TEST (0.1 GPH) <br />❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br />SAFE SUCTION SYSTEMS (NO VALUES IN BELOW GROUNDPIPING): <br />❑ 6. TRIENNIAL INTEGRITY TEST (0.1 GPH) <br />❑ 7. SELF MONITORING <br />SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUND PIPING): <br />GRAVITY FLOW <br />[17. SELF MONITORING <br />[19, BIENNIAL INTEGRITY TEST (0.1 GPH) <br />GRAVITY FLOW (Check all that apply): <br />[18. DAILY VISUAL MONITORING <br />[19. BIENNIAL INTEGRITY TEST (0.1 GPH) <br />SECONDARILY CONTAINED PIPING <br />SECONDARILY CONTAINED PIPING <br />PRESSURIZED PIPING (Check all that apply). <br />PRESSURIZED PIPING (Check all that apply): <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND <br />(Check one) <br />(Check one) <br />❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />❑ a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />® b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM <br />❑ b AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM <br />DISCONNECTION <br />DISCONNECTION <br />❑c. NO AUTO PUMP SHUT OFF <br />❑c NO AUTO PUMP SHUT OFF <br />® 11. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITH FLOW SHUTOFF OR <br />RESTRICTION <br />❑ 11. AUTOMATIC LEAK DETECTOR <br />® 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />SUCTION/GRAVITY SYSTEM <br />SUCTION/GRAVITY SYSTEM <br />❑ 13. CONTINUOUS SUMP SENSOR +AUDIBLE AND VISUAL ALARMS <br />❑ 13. CONTINUOUS SUMP SENSOR +AUDIBLE AND VISUAL ALARMS <br />EMERGENCY GENERATORS ONLY (Check all that apply) <br />EMERGENCY GENERATORS ONLY (Check all that apply) <br />❑ 14, CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF +AUDIBLE AND <br />❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF +AUDIBLE AND <br />VISUAL ALARMS <br />VISUAL ALARMS <br />❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW SHUT OFF OR <br />RESTRICTION <br />❑ 15. AUTOMATIC LINE LEAK DETECTOR 3 0 GPH TEST <br />( ) <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 17. DAILY VISUAL CHECK <br />[117. DAILY VISUAL CHECK <br />Vlll. DISPENSER CONTAINMENT <br />DISPENSER ❑ 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE <br />CONTAINMENT ❑ 4. DAILY VISUAL CHECK <br />DATE INSTALLED 466 ❑ 2. CONTINUOUS DISPENSER PAN SENSOR +AUDIBLE AND VISUAL ALARMS [15. TRENCH LINER/ MONITORING <br />1996 03. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER + ❑ 6. NONE <br />AUDIBLE AND VISUAL ALARMS 4ss <br />IX. OWNER/OPERATOR SIGNATURE <br />I certify that the information provided herein is true and accurate to the best of my knowledge. <br />SIGNATURE O NER/OPERATOR <br />DATE 1470 <br />NAME OF OWNER/OPRATOR (print) <br />TITLE OF OWNER/OPERATOR 472 <br />Ian Moorhead <br />Re ion Gasoline Environmental Compliance Manager <br />Permit Number (For local use only) 473 Permit Approved (For local use only) Permit Expiration Date (For local use only) <br />475 <br />UPCF (1/99 revised) Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.