My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STIMSON
>
2000
>
2800 - Aboveground Petroleum Storage Program
>
PR0516339
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/15/2019 2:51:03 PM
Creation date
8/13/2019 2:51:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0516339
PE
2832
FACILITY_ID
FA0003648
FACILITY_NAME
STKN ARMY AVIATION SUPP FACILITY*
STREET_NUMBER
2000
STREET_NAME
STIMSON
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
17726004
CURRENT_STATUS
01
SITE_LOCATION
2000 STIMSON RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SA N o J Q A Q U l N Environmental Health Department <br /> —COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Faclity Name: FacilityAtltlress: Date: <br /> STKN ARMYAVIATION SUPP FACILITY 2000 STIMSON RD STOCKTON August 08 2019 <br /> Other Violations <br /> Q1 See below Unlisted Administration/Documentation Notation .V .R .COS <br /> 4D2D See beim Unlisted Tm n in g Notation .V .R .COS <br /> 4030 See be. untiated OperationsWaintenance violation .V .R .COS <br /> 4040 See be. untiatetl Release/Leaks/Spills violation .V .R .COS <br /> 4D5D See belay unlisted AbandonmenMllegal Disposal/Unauthorized Treatment violation .V .R .COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1, CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 710 CFR 112.8(c)(6) Plan failed to adequately discuss procedures to test or inspect each container for integrity. <br /> The SPCC plan calls testing and inspections per the Steel Tank Institute(STI)SP-001 standard. The frequency and <br /> type of inspections is summarized in Table 3-1. Only the 20,000 gallon jet fuel tank and the 660 gallon diesel tank on <br /> the emergency generator are addressed. The testing or inspection of the mobile refuelers is not addressed. Table 3-1 <br /> does not mention annual inspections by the facility on an annual basis, as required by the STI SP-001 standard.The <br /> SPCC plan mentions weekly inspections in Table 3-1 and includes a daily inspection checklist, but the d onot meet <br /> the requirements of the STI -SP001 standard checklists. Each aboveground container shall be tested and inspected <br /> for integrity on a regular schedule and whenever repairs are made. The qualifications of personnel performing tests <br /> and inspections, frequency and type of testing and inspections that take into account container size, configuration, <br /> and design shall be determined in accordance with industry standards. Examples of these integrity tests include, but <br /> are not limited to: visual inspection, hydrostatic testing, radiographic testing, ultrasonic testing, acoustic emissions <br /> testing, or other systems of non-destructive testing. SPCC plan should address testing and inspections for integrity in <br /> accordance with an industry standard, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by September 7, 2019. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209) 468-3420. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION ATANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: August 08, 2019 Inspector: Inspector Phone: <br /> Name�-�—� Primed Nae and Titb: CESARRUVALCABA, REHS (209) 953-6213 <br /> Michael Gamino, !SG System Supervisor <br /> FA00038<8 PRO516339 SC(X)1 08I 2019 <br /> EHDM41 Rev.09Y =18 Pa9e4or4 Aboveground Petroleum Storage Act OR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 w .sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.