Laserfiche WebLink
k' ■ KLEINFELDER <br /> PROJECT SCHEDULE <br /> The proposed scope of work would be performed in accordance with the following <br /> approximate schedule. <br /> ' Approximate Task <br /> Timeline <br /> Week 0—2 Formal workplan authorization provided by the county health department, PG&E <br /> ' and Chevron forapplicable portions of the work Ian. <br /> Week 2—4 Permittin <br /> Week 4—9 Field Work <br /> ' Week 9— 11 Chemical Anal sis <br /> Week 11 — 15 Report Preparation <br /> Week 16 Report submitted to the Client <br /> Kleinfelder has no control over the time required by a regulatory agency, PG&E or Chevron <br /> Pipeline Company to review and approve a work plan or over the laboratory turn around time. <br /> s The excavation, transportation and disposal will be done by a separate contractor. Kleinfelder <br /> does not have control over scheduling or the progress of their field activities. <br /> CLIENT RESPONSIBILITIES AND ASSUMPTIONS <br /> ' This workplan is based on the following assumptions and responsibilities: <br /> ➢ This workplan will be adequate to obtain authorization from Pegasus, PG&E, <br /> ' Chevron, and regulatory agencies. If an addendum or an additional work plan is <br /> necessary, such as through a regulatory agency, additional charges for work <br /> plan preparation will be incurred. <br /> ' ➢ Adequate workspace and access will be provided. Kleinfelder will attempt to <br /> collect samples at the proposed locations. If the volume of contamination <br /> t exceeds the estimated amount additional confirmation sampling and analyses <br /> may be required for either confirmation sampling and or for additional profiling for <br /> disposal purposes. <br /> ' ➢ This workplan is based on the presumption that Pegasus MH Ventures I, along <br /> with oversight from Chevron and PG&E will clearly mark private subsurface <br /> ' structures existing onsite in the footprint area to determine the location of <br /> existing structures, underground utilities and services. Pegasus MH Ventures I <br /> should be aware that penetrating the site's surface is inherently risky. It is <br /> ' impossible to determine with certainty the precise location of all structures which <br /> may be buried in the ground. Kleinfelder's fee is not adequate to compensate for <br /> both the performance of the services and the assumption of risk of damage to <br /> such structures. Disruption of utilities or damage to underground structures will <br /> be the responsibility of Pegasus MH Ventures I or those responsible for <br /> identifying the pipeline locations (Chevron or PG&E). Services rendered by <br /> Kleinfelder to repair them will be billed at cost. Underground Service Alert (USA) <br /> at 1-800-642-2444 provides a partial location service free of charge for major <br /> utility lines. It is important that Pegasus MH Ventures I understand that <br /> 1 44843.T04/ST05R1333/DH:ly Page 14 of 17 <br /> ©2005 Kleinfelder, Inc. October 25,2005 <br />