mar VERIFICATION LABORATORY WYSIS <br /> TANK TANK TPH-G TPH-D BTX & E CL HC TOTAL MTBE METALS PCB <br /> N CONTENTS 8015 8015 8020 8010 LEAD Ta^•e" ICAP/ 8270 <br /> 8260 8260 8260 8240 7420 re AES or 8080 <br /> 7421 8020 AA <br /> 8260 <br /> LEADED GAS X X X X <br /> UNL GAS X X X <br /> DIESEL X X <br /> KEROSENE X X <br /> UNK FUEL X X X X X <br /> PROD. OIL X X <br /> CHLOR. i <br /> SOLVENTS ,X X <br /> NONCHLOR <br /> SOLVENTS X X X <br /> W ASl'E1 <br /> nsrn ott. r X X X r <br /> All analysis methods are the designated EPA methods described in EPA SW 846, Third Edition. Those methods not found In <br /> SW 846 are specifically noted below. Refer to the "SWRCB LUFT Field Manual", Appendix D (B), Table 3-5 on page A20 <br /> for mininnnn detection limits for motor vehicle fuel (gasoline and diesel). Refer to 1-2-3 'Regional Board Staff <br /> Recommendations for Initial Evaluation and Investigation of UST's" for the waste and motor oil minimum detection limits. <br /> Detection Limits thnt remnin below the MCL, STLC or Allowable Limit of the contaminant in question will be accepted, <br /> however laboratory shall utilize the most conservative method. <br /> I <br /> LATIORA FURY ANALYSES TERMINOLOGY: <br /> TPit-G Total Petroleum Hydrocarbon, Gasoline, GC/FID (5030) 8015 mod or GUMS 8260 <br /> 1 PTI IT Total Petroleum Hydrocarbon, Diesel, GC/FID (3550), 8015 mod or GUMS 8260 <br /> BTX & E Benzene, Toluene, Xylene & Ethyl Benzene, GC/PID 8020 or GC/MS 8260 <br /> CL TIC Chlorinated Hydrocarbon, GC/HSD 8010, GC/MS 8240 <br /> TOTAL L.FAD Total lead, AA 7420, AA 7421 or ICP-AES 6010 <br /> M1 BE Methyl Tertiary Butyl Ether, GC/PID 8020 and confirmed by GUMS 8260 <br /> MF_TALS [CAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption <br /> Spectrometry 7000. Metals: Cadmium, Chromium III and VI, Lead, Zine and Nickel. <br /> PCB Polychlorinated Biphenyls, GC/MS 8270 or 8080 <br /> GC FID Gas Chromatography, Flame Ionization Detection <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation, extraction method <br /> Method 5030 Purge and trip sample preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Nntc : L0 avoid false positive detection of benzene, benzene-Gee solvents are to be used. Fused capillary columns are <br /> preferred to packed columns; a packed column may be used as a "first cut' with 'dirty' samples or once the hytyoearbone have <br /> been characterized and proper QA/QC is followed. <br /> ror drinking water sources, FPA recommends that the 500 series for volatile organic should be used in preference to the 600 <br /> series because the, detection limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal <br /> contamination may require further analysis. PHS-EHD recommends holding those samples until disposal is indicated. <br /> Ell 23 046 (Revised (0%24/97) Page 9 <br />