My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2014 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
COMPLIANCE INFO 2014 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/21/2019 10:50:53 AM
Creation date
8/21/2019 9:39:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014 - 2016
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
286
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Maximize protection <br />vacuum <br />monitored secondary containment <br />system. <br />A Secondary Containment Vacuum <br />Sensing System for use with Veeder- <br />Root's ATG Systems. The Secondary <br />Containment Vacuum Sensing (SCVS) <br />System is designed to detect leaks in double - <br />walled tanks and piping systems while <br />helping to contain a release of product while <br />under vacuum. The system consists of: <br />• Vacuum Sensors, connected to tank, <br />sump or piping interstices <br />• A Submersible Turbine Pump (STP), <br />to provide a source of vacuum <br />• A Smart Sensor Interface with Embedded <br />Pressure Module in a TLS -350 <br />Monitoring System <br />The Vacuum Sensor is interfaced to Veeder- <br />Root's TLS -350 Monitoring System via <br />intrinsically safe wiring to provide system <br />status, replenish rate, alarm, and diagnostic <br />information. <br />Vacuum Sensor Kits are available in a variety <br />of models: <br />• For monitoring double -walled piping <br />and sump interstices <br />• For monitoring double -walled steel tank <br />interstices (see back page) <br />• For double -walled fiberglass tanks <br />These kits differ in the number of vacuum <br />sensors and the configuration of associated <br />liquid sensors. An inline kit mounted liquid <br />sensor is used for Vacuum Sensors <br />monitoring piping and sumps. An external <br />liquid sensor (to be installed in the secondary <br />space at the bottom of the tank) is provided <br />with one of the Vacuum Sensors in the steel <br />and fiberglass tank kits to monitor the tank. <br />VEEDER-ROOT <br />Features and Benefits <br />Satisfy Requirements <br />• Certified to meet California's requirement for <br />secondary space monitoring for tanks and lines <br />as required by AB 248 t a <br />• Satisfies, the requirements for C,iass I leak <br />Detection as defined by the European <br />Standard EN 13160-2 <br />• 3n1 Party, National Work Group and LG 113 <br />listed <br />Reduce Exposure to Risk <br />• <br />Alam -Ls when vacuum cannot be maintained <br />or when replenish rate exceeds 85 liters per hour <br />The system alarms when liquid is detected in <br />the secondary space, <br />Operating Temperature Rating: <br />-25 degrees C to +70 degrees C <br />Cable Length: <br />Sensor Dimensions: <br />5" high x 5" wide 2• deep <br />Facilitates periodic operability testing <br />I overage Existing Ueeder--Root Systems <br />• Uses STP as the vacuum source and works with <br />Fed Jacket and FE STPs <br />• Installs in the STP sump and connects to the <br />console via intrinsically safe wiring <br />• Able to share wiring conduit with other <br />Ueeder-Foot intrinsically safe (IS) probes and <br />sensors including sump or line leak sensors <br />• Interfaces to the Smart Sensor Interface with <br />Embedded Pressure Module <br />• Provides for positive shut down of pressurized <br />lines when required <br />• Simple installation, no need to mess with brine <br />Console Capability <br />The Vacuum Sensor is compatible with <br />the following consoles: <br />Console <br />TLS-350R/EMC w/BIR' <br />TLS -350 Plus/EMC Enhanced' <br />TLS-350/EMC' <br />'Upgrade Note: The Vacuum Sensor System requires <br />the console to have version 24C software (or greater) <br />along with an ECPU2 or ECPU w/ NVMEM 1 board. <br />Standard Models <br />Veeder-Root P/N Description <br />Acciassorjep°part; Description ,, , , Quantity/Length;;,;, ,,. ,.,'_,., ,,,; Part Npmber ,.,.;,,, <br />Vacuum Hose 25' 25' 332310-001 <br />Kits Include mounting bracket, 6' of vacuum lase, relief valve assembly (h required) and the appropriate number of liquid sensors, <br />3 -way bah valves, barbed fittings and hose clamps so that each vacuum sensor can monitor a single tank, sump or piping Interstices. <br />^ The Vacuum Sensing System requires one 7 channel Smart Sensor Interface with Embedded Pressure Module, 8 channel Smart <br />Sensor Modules (p/n 329356-004) can be used for Vacuum Sensors eight and above. <br />For more information call: 1-888-561-7942 <br />
The URL can be used to link to this page
Your browser does not support the video tag.