COMPLIANCE INFO 2017 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
COMPLIANCE INFO 2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/21/2019 11:07:05 AM
Creation date
8/21/2019 9:40:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
304
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification Form: Addendum for Vacuum/Pressure Interstitial Sensors <br />I. Results of Vacuum/Pressure Monitoring Equipment Testing <br />This page should be used to document testing and servicing of vacuum and pressure interstitial sensors. A copy of this <br />form must be included with the Monitoring System Certification Form, which must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the local <br />agency regulating UST systems within 30 days of test date. <br />Manufacturer: VEEDER ROOT <br />Model: TLS -350 <br />System Type: ❑ Pressure; ® Vacuum <br />Sensor ID <br />l � • <br />_' `� jt <br />„" , r .��= ..�'. ..: � � ��� <br />�.--,.err ��r'-� �� ...�% � y,.�;�� <br />Component(s) Monitored by this Sensor: 87 PRODUCT LINE <br />S - 1 <br />Sensor Functionality Test Result: ® Pass; ❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; <br />❑ Fail <br />Component(s) Monitored by this Sensor: N / A <br />S - 2 <br />Sensor Functionality Test Result: ❑ Pass; ❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; <br />❑ Fail <br />Component(s) Monitored by this Sensor: 91 PRODUCT LINE <br />S-3 <br />Sensor Functionality Test Result: ® Pass; ❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; <br />❑ Fail <br />Component(s) Monitored by this Sensor: VENT LINES <br />S-4 <br />Sensor Functionality Test Result: ❑ Pass; ® Fail <br />Interstitial Communication Test Result: ❑ Pass; <br />❑ Fail <br />Component(s) Monitored by this Sensor: 87 / 91 VAPOR RETURN LINE <br />S -5 <br />Sensor Functionality Test Result: ® Pass; ❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; <br />❑ Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; ❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; <br />❑ Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; ❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; <br />❑ Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; ❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; <br />❑ Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; ❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; <br />❑ Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; ❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; <br />❑ Fail <br />How was interstitial communication verified? <br />® Leak Introduced at Far End of Interstitial Space;' ❑ Gauge; <br />® Visual Inspection; ❑ Other (Describe in Sec. <br />J, below) <br />Was vacuum/pressure restored to operating levels in all interstitial spaces? ® Yes ❑ No (If no, describe in Sec. J, below) <br />,T. Comments: S-4 HI LIQUID FAILED, DISPENSERS TESTED FOR COMM. NO TANK COMMUNICATIONS <br />TESTED <br />' If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the <br />sensor, vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br />UN -036A - 1/1 www.unidocs.org Rev. 01/26/06 <br />