Laserfiche WebLink
ED <br /> Monitoring System Certification Form: Addendum for Vacuum/Pressure Interstitial Sensors 2017 <br /> I. Results of Vacuum/Pressure Monitoring Equipment Testing ENVIR0N&4ENIAL HEgLTM <br /> This page should be used to document testing and servicing of vacuum and pressure interstitial sensjr6T6j fFUW$ <br /> form must be included with the Monitoring System Certification Form, which must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the local <br /> agency regulating UST systems within 30 days of test date. <br /> Manufacturer: VEEDER ROOT Model: TLS-350 System Type: ❑Pressure; ® Vacuum <br /> Sensor ID <br /> Component(s)Monitored by this Sensor: 87 line <br /> s1 <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: vapor line <br /> s2 <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: 91 line <br /> S3 <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: vents <br /> s4 <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fai I <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> How was interstitial communication verified? <br /> ® Leak Introduced at Far End of Interstitial Space;' ❑ Gauge; ❑ Visual Inspection; ® Other(Describe in Sec. J, <br /> below <br /> Was vacuum/pressure restored to operating levels in all interstitial spaces? ®Yes ❑No(If no, describe in Sec. J, below) <br /> J. Comments: 4-10-17 COULD NOT TEST COMUNICATION ON STP AND FILL SUMPS ELITE WILL REPAIR <br /> AND TEST <br /> 4-10-17 Waterloo Shell 4315 E Waterlood Rd Stockton <br /> Page 4 of 4 <br /> ' If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the <br /> sensor,vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br /> UN-036A-1/1 www.unidoes.org Rev.01/26/06 <br />