Laserfiche WebLink
i <br /> -� Effluent Sample � <br /> A sample port for the effluent is located in the exhaust stack of t <br /> the Remox system. The flow pressure from the exhaust is great <br /> enough to fill a tedlar bag. Sterile poly tubing is fitted to the <br /> exhaust port and the tedlar bag. Then the sample valve of the <br /> tedlar bag is opened and the bag is filled with the sample. Once <br /> the tedlar bag is full, the valve is closed and locked, the sample # <br /> port closed, and the appropriate label is placed on the bag. <br /> The labels for both the influent and effluent tedlar bag samples <br /> show the date time sample p e ID# and analyses to be run. <br /> Both the influent and effluent tedlar bag samples are then placed <br /> within a cooler, on ice, and are hand delivered to WEGE' s laboratory <br /> that same day. <br /> i <br /> f The vapor sample is then injected into an FID (Flame Ionizing <br /> Detector) chromatograph and the resulting chromatogram compared to . t <br /> standard chromatograms of known TFH (Total Fuel Hydrocarbons, <br /> gasoline) and BTEX (benzene, toluene, ethylbenzene, and xylenes) ' <br /> concentrations . A duel chromatograph comparison is also ran <br />' (Photovac 1OS50) to evaluate BTEX, TCE, PCE, and DCE. <br /> I <br /> ON SITE ANALYSIS <br /> Besides bag samples collected for the WEGE laboratory some samples <br /> may be run on site using a Photovac 10550 PID chromatograph. f <br /> The influent and effluent samples are collected from the same ports <br /> as the bag samples but 60 cc syringes are used to collect the sample <br /> and 0 . 5 cc of the vapor sample are then injected directly into the <br /> PID chromatograph. The resulting chromatogram is then compared to a <br /> r standard run on the same chromatograph prior to the sample run. <br /> During the initial month' of operation, three effluent samples were <br /> obtained during the day and analyzed using the lOS50 chromatograph. { <br /> j The highest value is used to calculate the VOC poundage per day <br /> produced. Presently, an influent and an effluent sample are <br /> obtained upon arrival to the site . Adjustments are then made to the <br /> vapor extraction system: removal of liquids from the condensation <br /> traps; closing the air dilute valve to maximize vapor removal, <br /> without causing the REMOX Unit to shut down due to high temperature <br /> shut off (greater than 17500F) ; and closing the pump bypass to <br /> create maximum flow and vacuum from the wells . Once, these <br /> adjustments have been completed and the system has stabilized, <br /> influent and effluent samples are again obtained, along with samples <br /> from the individual extraction orifices (wells) . The site is then <br /> secured until the next visit . <br />�4 <br /> k <br /> page 3 of R603, 12/16/93 <br />