approximately 64 cfm <br /> COLLECTING SAMPLES <br /> The sample is obtained from a sample port located, prior to the <br /> vacuum pump from a sample port on the flow meter orifice . Sterile <br /> poly tubing was used to attach a one liter tedlar bag, fitted <br /> with a special septum "valve" and tubing bib, to the sample port . <br /> The sample port is on the vaccum side of the pump and therefore a <br /> vacuum greater than the well vacuum must be exerted on the <br /> outside of the tedlar bag to "fill" the bag with the vapor <br /> sample A special vacuum box, in which the tedlar bag is sealed <br /> inside, is used to exert a high vacuum to the exterior of the <br /> bag, thereby pulling a sample into the bag Once the tedlar bag <br /> is filled, its valve is closed and locked and the appropriate <br /> label is placed on the bag <br /> The label shows the date, time, sample ID# and analyses to be run <br /> and the sampler' s initials The tedlar bag samples are then <br /> placed within a cooler, and are hand delivered to WEGE' s <br /> laboratory that same day <br /> The vapor sample is then infected into an FID (Flame Ionizing <br /> Detector) chromatograph and the resulting chromatogram compared <br /> to standard chromatograms of known TPHg (Total Petroleum <br /> Hydrocarbons, gasoline) and BTEX (benzene, toluene, ethylbenzene, <br /> and xylenes) concentrations . Selected samples are also analyzed <br /> by second column chromatograph comparison A Photovac 10550 <br /> photo-ionizing gas chromatograph was used to evaluate BTEX, TCE, <br /> PCE, and DCE . <br /> Carbon dioxide (CO2) concentration is measured from the tedlar <br /> bag samples by connecting a Drager tube and pump to the <br /> inlet/outlet of the tedlar bag CO2 reading in percent is then <br /> obtained and recorded on the chrmoatogram produced from the GC-- <br /> FID analysis . <br /> Vapor Recovery System Monitoring and Sampling <br /> INFLUENT SAMPLE <br /> The influent sample is obtained from a sample port located on the <br /> pressure side of the blower A 1 liter tedlar bag, fitted with a <br /> special septum vui�.. <br /> t.,.,, "valve" and t,;hir�rr 1-1-ibb , s attach the sample port <br /> with sterile poly tubing Then the sample valve of the tedlar <br /> bag is opened and the bag is filled with the sample . Once the <br /> tedlar bag is full, the valve is closed and locked, the sample <br /> port closed, and the appropriate label is placed on the bag <br /> MW1 , MW2/3 , EX AND MW10 VAPOR RECOVERY LATERAL SAMPLES <br /> Sample ports are located at the orifice plate for each lateral , <br /> these laterals are under vacuum A 1 liter tedlar bag, fitted <br /> 4 R603 APPEND. E <br />