Laserfiche WebLink
08/18/93 <br /> Unit restarted, <br /> 08/20/93 <br /> Unit running on arrival . Adjust unit and sample. Collect bag <br /> samples of MWS., MW2/3, MW10, Convault, influent, and effluent <br /> for WEGE laboratory System set at 17o air dilute <br /> 08/23/93 <br /> Unit running on arrival Adjust unit and sample Collect bag <br /> sample of influent for WEGE laboratory. System set at Ot air <br /> dilute . <br /> Vacuum pump Making loud nose, shut down system for repairs <br /> The VOC emissions have never exceeded the 52 lb/day emission limit <br /> for the site. No evidence of Tetrachloroethylene (PCE) was found <br /> during examination of the chromatograms of the samples taken to the <br /> WEGE laboratory. <br /> VAPOR SAMPLING <br /> COLLECTING LABORATORY SAMPLES <br /> Influent Sample <br /> The influent sample is obtained from a sample port located after the <br /> system vacuum pump before the REMOX Unit Sterile poly tubing is <br /> then used to attach a 1 liter tedlar bag, fitted with a special <br /> septum "valve" and tubing bib, to the sample port The sample port <br /> is on the pressure side of the pump and therefore the bag will fill <br /> without need of a pump. Once the tedlar bag is filled, its valve is <br /> Closed and locked; the appropriate label is placed on the tedlar <br /> bag. <br /> s <br /> page 2 of R603 , 09/14/93 <br />