Laserfiche WebLink
RESULTS <br /> See Table 1 for the results of REMOX operation and Table 2 for <br /> results influent/effluent monitoring of the system. <br /> CONCLUSIONS <br /> The VOC emissions during current REMOX operations for the period <br /> 10/10/91 to 12/09/92, have not exceeded the 52 lb/day limit . No DCE, <br /> TCE or PCE has been detected in the samples <br /> The average Natural Gas usage to 7/20/92 was 2 . 2 cfm, or 3168 cf per <br /> operational day, following the exchange of the unit on 8/18/92 the <br /> average Natural Gas usage has been 6 1 cfm or 8 , 852 cfd, which is <br /> below the permit limit of 17, 280 cfd. <br /> A total of 53766 pounds of gasoline have been destroyed during <br /> operation of the vapor recovery system <br /> The system is currently destoring, as of 01/19/92 , 301 1 lb/day of <br /> hydrocarbon It is also recovering CO2 at the rate of 1.92 lb <br /> hydrocarbon a day, oxidized <br /> Butler <br /> Geologist <br /> CC. <br /> Tom Peterson <br /> San Joaquin Valley Unified Air Pollution Control District <br /> P O Box 2009 <br /> Stockton, California 95201 <br /> Mary F Meays <br /> Public Health Services <br /> P O. Box 2009 <br /> Stockton, California 95201 <br /> page 6 of R603, 01/26/93 <br />