BILLING PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
BILLING PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2023 11:45:15 AM
Creation date
8/23/2019 11:27:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r' „w r , <br />STATE OF CALIFORNIA <br />STATE WATER RESOURCES CONTROL BOARD W <br />UNDERGROUND STORAGE TANK PERMIT APPLICATION • FORM B <br />COMPLETE A SEPARATE FORM FOR EACH K SYSTEM. <br />MARK ONLY ❑ 1 NEW PERMIT 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br />ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED <br />DBA OR FACILITY NAME WHERE TANK IS INSTALLED: l -:� Is Qc, ' loo S ke- I) <br />I. TANK DESCRIPTION COMPLETE ALL ITEMS •- SPECIFY IF UNKNOWN <br />A. OWNER'S TANK I. D. # c <br />J <br />B. MANUFACTURED BY: <br />C. DATE INSTALLED (MO/DAYNEAR) ' cl <br />( <br />D. TANK CAPACITY IN GALLONS: Oi <br />ILTANKCONTENTS IFA -1 IRMARKFD COMPI FTPITEMC <br />A. OTOVEHICLE FUEL 4 OIL <br />B. <br />C. ❑ 1. REG LAR 3 DIESEL ❑ 6 AVIATION GAS <br />❑ 95 UNKNOWN <br />SYSTEM <br />❑ 4 GASAHOL <br />2 PETROLEUM ❑ 80 EMPTY <br />��PRODUCT <br />❑ lbPREMIIUM❑ 5 JET FUEL ❑ 7 METHANOL <br />UNLEADED <br />❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN <br />❑ 2 WASTE <br />❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br />D. IF (A.1) IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C. A. S. #: <br />III. TANK CONSTRUCTION MARK ONF ITFM ONI Y IN ROXFS A R AND C AND Al I THAT APPI IFR IN ROY O AND F <br />A. TYPE OF <br />❑-1 DOUBLE WALL <br />F--]3 SINGLE WALL WITH EXTERIOR LINER <br />❑ 95 UNKNOWN <br />SYSTEM <br />[ 2 SINGLE WALL <br />/j / <br />❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) <br />❑ 99 OTHER <br />B. TANK <br />E?` -1 -BARE STEEL <br />❑ 2 STAINLESS STEEL <br />❑ 3 FIBERGLASS <br />❑ 4 STEEL CLAD W/ FIBERGLASS REINFORCED PLASTIC <br />MATERIAL <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />❑ 7 ALUMINUM <br />❑ 8 1009/6 METHANOL COMPATIBLE W/FRP <br />(PrimaryTank) <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />L;;;95 -UNKNOWN <br />❑ 99 OTHER <br />❑ 1 RUBBER LINED <br />❑ 2 ALKYD LINING <br />❑ 3 EPDXY LINING <br />❑ 4 PHENOLIC LINING <br />C. INTERIOR <br />❑ 5 GLASS LINING <br />❑ 6 UNLINED <br />LJ UNKNOWN <br />❑ 99 OTHER <br />LINING <br />/ <br />- <br />IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? <br />YES ✓ NO <br />D. CORROSION <br />❑ 1 POLYETHYLENE WRAP <br />❑ 2 COATING <br />❑ 33 VINYL WRAP <br />❑ 4 FIBERGLASS REINFORCED PLASTIC <br />PROTECTION <br />[7]5 CATHODIC PROTECTION <br />F-]91 NONE <br />�'95 UNKNOWN <br />❑ 99 OTHER <br />E. SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED (YEAR) <br />OVERFILL PREVENTION EQUIPMENT INSTALLED (YEAR) <br />IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND BOTH IF APPI ICARI F <br />A. SYSTEM TYPE <br />A U <br />1 SUCTION <br />A& 2 PRESSURE <br />A U <br />3 GRAVITY A U 99 OTHER <br />B. CONSTRUCTION <br />A <br />1 SINGLE WALL <br />A U 2 DOUBLE WALL <br />A U <br />3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br />C. MATERIAL AND <br />CORROSION <br />PROTECTION <br />A U <br />A U <br />A U <br />1 BARE STEEL <br />5 ALUMINUM <br />9 GALVANIZED STEEL <br />A U 2 STAINLESS STEEL A U <br />A U 6 CONCRETE A U <br />A U 10 CATHODIC PROTECTION <br />3 POLYVINYL CHLORIDE (PVC) A U <br />7 STEEL W/COATING A U <br />A U 95 UNKNOWN A U <br />4 FIBERGLASS PIPE <br />8 1009/6 METHANOL COMPATIBLE W/FRP <br />99 OTHER <br />D. LEAK DETECTION <br />❑ 1 <br />AUTOMATIC LINE LEAK DETECTOR2 LINE TIGHTNESS TESTING ❑ 3 MONITORINGINTERSTITIAL <br />❑ 99 OTHER <br />i/ T�\11/ � rel/ f1rTrAT1f1\1 <br />V. 1PAINIM LCHI1% VC1 CliI IV1V <br />❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br />❑ 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br />VI. TANK CLOSURE INFORMATION <br />1. ESTIMATED DATE LAST USED (MO/DAY/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH YES ❑NO <br />SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br />THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br />APPLICANTS NAME DATE <br />(PRINTED A SIGNATURE) <br />LOCAL AGENCY USE ONLY THE STATE I.D. NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br />COUNTY # JURISDICTION # FACILITY # TANK # <br />STATE I.D.# � = 6 b _)cr-9 <br />PERMITNUMBER PERMIT APPROVED BY/DATE MITZEEXXP.IRgTTIION ATE <br />THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION • FORM A, UNLESS A CURRENT FORM A HAS BEEN FILED. <br />FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS / <br />FORM B (12-91) ? 'f G'v <br />FOR0034M6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.