BILLING PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
BILLING PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2023 11:45:15 AM
Creation date
8/23/2019 11:27:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I �o� <br /> IED PROGRAM CONSOLIDATED FORM T : TA0515769 <br /> PR#: PRO231760 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 FAC#: FA0003831 <br /> (two pages per tank) <br /> TYPE OF ACTION Page 4 of 5 <br /> (Check only hem only) ❑ I NEW SITE PERMIT ❑4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑6 TEMPORARY SITE CLOSURE <br /> ❑7 PERMANENTLY CLOSED ON SITE <br /> ❑3 RENEWAL PERMIT (Specify reason-for local use Dole) (Specify reason-for local use only) ❑g TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: PR#: 1 <br /> WATERLOO SHELL* 3 FA0003831 PR0231760 <br /> LOCATION WITHIN SITE(opeone) 4315 WATERLOO RD,STOCKTON 431 <br /> PHONE <br /> L TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 9 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK [:]Yes ❑No 434 <br /> TA0515769 XERXES If"Yes",complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 417 <br /> 1/1/2005 12:00:OOAM 12,000 1 <br /> ADDITIONAL DESCRIPTION(For local use only) 439 <br /> 11.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® 1.MOTOR VEHICLE FUEL a. UNLEADED ❑2.LEADED ❑5.JET FUEL <br /> (If marked complete Petroleum Type) <br /> :X:Ib.P IUM UNLEADED ❑3.DIESEL ❑6.AVIATION FUEL <br /> ❑2.NON-FUEL PETROLEUM c.MIDGRADE UNLEADED ❑4.GASOHOL ❑99.OTHER <br /> ❑3.CHEMICAL PRODUCT <br /> 4.HAZARDOUS WASTE COMMON NAME(from Hamrdous Materials Inventory page) 441 CAS#(from Hamrdous Materials Inventory page) 442 <br /> ❑ <br /> (Includes Used Oil) <br /> ❑95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑3.SINGLE WALL WITH ❑5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LIVER ❑95.UNKNOWN <br /> X❑2 DOUBLE WALL ❑4.SINGLE WALL IN VAULT ❑99.OTHER <br /> TANK MATERIAL-primary tank ❑ I.BARE STEEL ❑FIBERGLASS/PLASTIC ❑5.CONCRETE ❑95.UNKNOWN 444 <br /> (Check one item only) ❑2.STAINLESS STEEL ❑STEEL CLAD W/FIBERGASS ®8.FRP COMPTIBLE W/1001%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑99.OTHER <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL ❑3.FIBERGLASS/PLASTIC ❑5.CONCRETE ❑95.UNKNOWN 445 <br /> (Check one item only) ❑2.STAINLESS STEEL ❑4.STEEL CLAD W/FIBERGLASS ®8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10 COATED STEEL ❑99.OTHER <br /> ❑5.CONCRETE <br /> TANK INTERIOR LINING ❑ L RUBBER LINED ❑3.EPDXY LINING E]5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED <br /> OR COATING <br /> (Check one item only) ❑2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED ❑99.OTHER <br /> (For local use only) <br /> OTHER CORROSION ❑ I MANUFACTURING CATHODIC ❑3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 DATE INSTALLED 44' <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Check one item only) [j4 IMPRESSED CURRENT ❑99 OTHER <br /> ❑2 SACRIFICIAL ANODE (For tical use only) <br /> SPILL AND OVERFILL YEAR INSTALLE050 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that ® I SPIN.CONTAINMENT 2,005.00 ❑ 1 ALARM ® 3 FILL TUBE SHUT OFF VALv 2,005.00 <br /> apply) © 2 DROP TUBE 2,005,00 <br /> ❑2 BALL ❑4 EXEMPT <br /> ® 3 STRIKER PLATE 2,005.00 SAT <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGE WALL TANK(Check all that apply) <br /> 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) (Check one item only) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ❑ I VISUAL(SINGE WALL IN VAULT ONLY) <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR)BIENNIAL TANK TESTING E]3 MANUAL MONITORING <br /> ❑99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 4D QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? +S7 <br /> 1/1/2005 12:00:OOAM 55 ESTIMATE0.00 gallons ❑Yes ❑No <br /> UPCF(12/99 revised) <br />