Laserfiche WebLink
L.._,r'IED PROGRAM CONSOLIDATED FO S G 13 �r <br />TANKS <br />UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br />(Two pages per tank) <br />Page 2 of 5 <br />TYPE OF ACTION ❑ 1. NEW PERMIT ❑ 4. AMENDED PERMIT ® 5. CHANGE OF INFORMATION ❑ 6. TEMPORARY TANK CLOSURE 430. <br />(Check one item only) ❑ 3. RENEWAL PERMIT ❑ 7. PERMANENTLY CLOSED ON SITE <br />(Specify reason) (Specify reason) ® 8. TANK REMOVED <br />-] - <br />BUSINESS NAME (Same as FACILITY NAME or DBA - Doing Business As) 3. FACILITY ID: <br />I <br />Waterloo Shell �' 99--31 <br />1 <br />LOCATION WITHIN SITE (Optional) 431. <br />4315 Waterloo Road, Stockton, CA <br />I. TANK DESCRIPTION <br />(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br />TANK ID #7;q 0505 387 432' <br />TANK MANUFACTURER 433. <br />COMPARTMENTALIZED TANK ❑ Yes ® No 434. <br />136143 - Premium <br />Xerxes <br />If "Yes," complete one page for each compartment. <br />DATE INSTALLED 435. <br />TANK CAPACITY IN GALLONS 436• <br />NUMBER OF COMPARTMENTS <br />(YEAR/MO) <br />437. <br />1995 <br />15,000 <br />one <br />ADDITIONAL DESCRIPTION (For local use only) 438. <br />II. TANK CONTENTS <br />TANK USE 439. <br />PETROLEUM TYPE 440. <br />® 1. MOTOR VEHICLE FUEL <br />® la. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br />(If checked, complete Petroleum Type) <br />❑ ib. PREMIUM UNLEADED ❑ 3. DIESEL ❑ 6. AVIATION GAS <br />❑ 2. NON-FUEL PETROLEUM <br />❑ lc. MIDGRADE UNLEADED ❑ 4. GASOHOL ❑ 99. OTHER: <br />❑ 3. CHEMICAL PRODUCT <br />COMMON NAME (from Hazardous Materials Inventory page) 441• <br />CAS# (from Hazardous Materials Inventory page) 442. <br />❑ 4. HAZARDOUS WASTE <br />n/a <br />n/a <br />(Includes Used Oil) <br />❑ 95. UNKNOWN <br />III. TANK CONSTRUCTION <br />TYPE OF TANK ❑ 1. SINGLE WALL ❑ 3. SINGLE WALL WITH EXTERIOR [15. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br />(Check one item only) MEMBRANE LINER ❑ 95. UNKNOWN <br />® 2. DOUBLE WALL ❑ 4. SINGLE WALL IN A VAULT ❑ 99. OTHER <br />TANK MATERIAL -primary tank [11. BARE STEEL 03. FIBERGLASS / PLASTIC ❑ 5. CONCRETE ❑ 95. UNKNOWN 444. <br />(Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS ❑ 8. FRP COMPATIBLE ❑ 99. OTHER: <br />REINFORCED PLASTIC FRP W/100% METHANOL <br />TANK MATERIAL - secondary tank ❑ I. BARE STEEL ® 3. FIBERGLASS/ PLASTIC ❑ 8. FRP COMPTIBLE W/100% METHANOL ❑ 95. UNKNOWN 445. <br />(Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS [39. FRP NON-CORRODABLE JACKET ❑ 99. OTHER <br />REINFORCED PLASTIC (FRP) ❑ 10. COATED STEEL <br />❑ 5. CONCRETE <br />TANK INTERIOR LINING ❑ 1. RUBBER LINED ❑ 3. EPDXY LINING ❑ 5. GLASS LINING ❑ 95. UNKNOWN 446. <br />DATE INSTALLED 447. <br />OR COATING ❑ 2. ALKYD LINING ❑ 4. PHENOLIC LINING ® 6. UNLINED ❑ 99. OTHER <br />Check one item only) <br />OTHER CORROSION ❑ 1. MANUFACTURED CATHODIC ® 3. FIBERGLASS REINFORCED PLASTIC ❑ 95. UNKNOWN 448. <br />DATE INSTALLED 449. <br />PROTECTION PROTECTION ❑ 4. IMPRESSED CURRENT ❑ 99. OTHER <br />[f A licable ❑ 2. SACRIFICIAL ANODE <br />SPILL AND OVERFILL YEAR INSTALLED 45o. <br />TYPE 451. <br />OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br />(Check all that apply) ❑ 1. SPILL CONTAINMENT <br />❑ 1. ALARM ❑ 3. FILL TUBE SHUT OFF VALVE <br />❑ 2. DROP TUBE <br />❑ 2. BALL FLOAT ❑ 4. EXEMPT <br />® 3. STRIKER PLATE 1995 <br />Xerxes <br />IV. TANK LEAK DETECTION <br />(A description of the monitoring program shall be submitted to the local agency.) <br />IF SINGLE WALL TANK 453• <br />IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br />(Check all that apply) <br />(Check one item only) <br />❑ 1. VISUAL (EXPOSED PORTION ONLY) ❑ 5. MANUAL TANK GAUGING (MTG) <br />❑ 1. VISUAL (SINGLE WALL IN VAULT ONLY) <br />❑ 2. AUTOMATIC TANK GAUGING (ATG) ❑ 6. VADOSE ZONE <br />CONTINUOUS INTERSTITIAL MONITORING <br />❑ 3. CONTINUOUS ATG ❑ 7. GROUNDWATER <br />❑ 3. MANUAL MONITORING <br />❑ 4. STATISTICAL INVENTORY RECONCILIATION [18. TANK TESTING <br />(SIR) + BIENNIAL TANK TESTING ❑ 99. OTHER <br />V. TANK CLOSURE INFORMATION / PERMANENT <br />CLOSURE IN PLACE <br />ESTIMATED DATE LAST USED (YR/MO/DAY) 455. <br />ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. <br />TANK FILLED WITH INERT MATERIAL? 457. <br />CURRENTLY IN USE <br />N/A gallons <br />❑ Yes ❑ No <br />UPCF hwfwrc-b (1/99) -1/4 http://www.unidoes.org Rev. 02/16/00 <br />