My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
BILLING PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2023 11:45:15 AM
Creation date
8/23/2019 11:27:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 7T <br />1 1 -3 ay <br />L. -,DIED PROGRAM CONSOLIDATED FO , <br />TANKS <br />UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br />(Two pages per tank) <br />Page 4 of 5 <br />TYPE OF ACTION ❑ 1. NEW PERMIT ❑ 4. AMENDED PERMIT ® 5. CHANGE OF INFORMATION ❑ 6. TEMPORARY TANK CLOSURE 430. <br />(Check one item only) ❑ 3. RENEWAL PERMIT ❑ 7. PERMANENTLY CLOSED ON SITE <br />(Specify reason) (Specify reason) ® 8. TANK REMOVED <br />BUSINESS NAME (Same as FACILITY NAME or DBA -Doing Business As) 3. <br />FACILITY ID: <br />1. <br />Waterloo Shell <br />3 <br />LOCATION WITHIN SITE (Optional) 431. <br />4315 Waterloo Road, Stockton, CA <br />1. TANK DESCRIPTION <br />(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br />TANK ID # TA6.ro6 432. <br />TANK MANUFACTURER 433. <br />COMPARTMENTALIZED TANK ❑ Yes ® No 434. <br />136143 - Regular 7 <br />Xerxes <br />If "Yes," complete one page for each compartment. <br />DATE INSTALLED 435• <br />TANK CAPACITY IN GALLONS 436• <br />NUMBER OF COMPARTMENTS <br />(YEAR/MO) <br />437. <br />1995 <br />15,000 <br />one <br />ADDITIONAL DESCRIPTION (For local use only) 438. <br />11. TANK CONTENTS <br />TANK USE 439• <br />PETROLEUM TYPE 440. <br />® 1. MOTOR VEHICLE FUEL <br />® la. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br />(If checked, complete Petroleum Type) <br />❑ lb. PREMIUM UNLEADED ❑ 3. DIESEL ❑ 6. AVIATION GAS <br />❑ 2. NON -FUEL PETROLEUM <br />❑ lc. MIDGRADE UNLEADED ❑ 4. GASOHOL [199. OTHER: <br />❑ 3. CHEMICAL PRODUCT <br />COMMON NAME (from Hazardous Materials Inventory page) 441. <br />CAS# (from Hazardous Materials Inventory page) 442. <br />❑ 4. HAZARDOUS WASTE <br />n/a <br />n/a <br />(Includes Used Oil) <br />❑ 95. UNKNOWN <br />M. TANK CONSTRUCTION <br />TYPE OF TANK [11. SINGLE WALL ❑ 3. SINGLE WALL WITH EXTERIOR ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br />(Check one item only) MEMBRANE LINER ❑ 95. UNKNOWN <br />® 2. DOUBLE WALL [34. SINGLE WALL IN A VAULT ❑ 99. OTHER <br />TANK MATERIAL - primary tank ❑ 1. BARE STEEL 193. FIBERGLASS / PLASTIC ❑ 5. CONCRETE ❑ 95. UNKNOWN 444. <br />(Check one item only) ❑ 2. STAINLESS STEEL [14. STEEL CLAD W/FIBERGLASS ❑ 8. FRP COMPATIBLE ❑ 99. OTHER: <br />REINFORCED PLASTIC FRP W/100%METHANOL <br />TANK MATERIAL - secondary tank ❑ 1. BARE STEEL 03. FIBERGLASS/ PLASTIC ❑ 8. FRP COMPTIBLE W/100% METHANOL ❑ 95. UNKNOWN 445. <br />(Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS ❑ 9. FRP NON-CORRODABLE JACKET ❑ 99. OTHER <br />REINFORCED PLASTIC (FRP) ❑ 10. COATED STEEL <br />❑ 5. CONCRETE <br />TANK INTERIOR LINING ❑ 1. RUBBER LINED ❑ 3. EPDXY LINING ❑ 5. GLASS LINING ❑ 95. UNKNOWN 446. <br />DATE INSTALLED 447. <br />OR COATING ❑ 2. ALKYD LINING ❑ 4. PHENOLIC LINING ® 6. UNLINED ❑ 99. OTHER <br />Check one item only) <br />OTHER CORROSION ❑ 1. MANUFACTURED CATHODIC ® 3. FIBERGLASS REINFORCED PLASTIC [195. UNKNOWN 448. <br />DATE INSTALLED 449. <br />PROTECTION PROTECTION ❑ 4. IMPRESSED CURRENT ❑ 99. OTHER <br />If Applicable) ❑ 2. SACRIFICIAL ANODE <br />SPILL AND OVERFILL YEAR INSTALLED 45o. <br />TYPE 451. <br />OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br />(Check all that apply) ❑ 1. SPILL CONTAINMENT <br />[11. ALARM ❑ 3. FILL TUBE SHUT OFF VALVE <br />❑ 2. DROP TUBE <br />❑ 2. BALL FLOAT ❑ 4. EXEMPT <br />® 3. STRIKER PLATE 1995 <br />Xerxes <br />IV. TANK LEAK DETECTION <br />(A description of the monitoring program shall be submitted to the local agency.) <br />IF SINGLE WALL TANK 453• <br />IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br />(Check all that apply) <br />(Check one item only) <br />❑ 1. VISUAL (EXPOSED PORTION ONLY) ❑ 5. MANUAL TANK GAUGING (MTG) <br />❑ 1. VISUAL (SINGLE WALL IN VAULT ONLY) <br />❑ 2. AUTOMATIC TANK GAUGING (ATG) ❑ 6. VADOSE ZONE <br />, . 2. CONTINUOUS INTERSTITIAL MONITORING <br />❑ 3. CONTINUOUS ATG [17. GROUNDWATER <br />❑ 3. MANUAL MONITORING <br />❑ 4. STATISTICAL INVENTORY RECONCILIATION [18. TANK TESTING <br />(SIR) + BIENNIAL TANK TESTING ❑ 99. OTHER <br />V. TANK CLOSURE INFORMATION / PERMANENT <br />CLOSURE IN PLACE <br />ESTIMATED DATE LAST USED (YR/MO/DAY) 455. <br />ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. <br />TANK FILLED WITH INERT MATERIAL? 457. <br />CURRENTLY IN USE <br />N/A gallons <br />❑ Yes ❑ No <br />UPCF hwfwrc-b (1/99) -1/4 http://www.unidocs.org Rev. 02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.