Laserfiche WebLink
INDIVID <br />TEST DATE: 03/09/01 <br />CLIENT: EQUIVA SERVICES, LLC <br />Tank ID: <br />1 <br />Product: <br />PREMIUM <br />Capacity in gallons: <br />14,976 <br />Diameter in inches: <br />120.00 <br />Length in inches: <br />277 <br />Material: <br />DW FIBERG <br />COMMENTS <br />PSI at tank bottom: <br />Fluid level in inches: <br />UFT/OFT: <br />Fluid volume in gallons: <br />Tank water level in inches: <br />Test time: <br />Number of thermisters: <br />Specific gravity: <br />Water table depth in inches: <br />Determined by (method): <br />Leak rate in gph: <br />Result: <br />COMMENTS <br />Test time: <br />Wage volume: <br />Ullage pressure: <br />Results: <br />TANK INFORMATION AND <br />3'� Tank��o%gy <br />8900 SHOAL CREEK, BUILDING 200 <br />AUSTIN, TEXAS 78757 (512) 451-6334 <br />Tank manifolded: NO <br />Vent manifolded: NO <br />Vapor recovery manifolded: YES <br />Overfill protection: yES <br />Overspill protection: yE5 <br />Installed: ATG <br />CP installed on: / / <br />NOT <br />TESTED <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: NOT <br />Flow rate (cfh): TESTED <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />COMMENTS <br />Make: <br />Model: <br />S/N: <br />Open time in sec: <br />Holding psi: <br />Resiliency cc: <br />est leak rate ml/m: <br />Metering psi: <br />Calib. leak in gph: <br />Results: <br />COMMENTS <br />EST RESULTS <br />WORK ORDER NUMBER: 2215974 <br />SITE: SHELL 204-7524-2804 <br />Bottom to top fill in inches: <br />175.0 <br />Bottom to grade in inches: <br />183.0 <br />Fill pipe length in inches: <br />55.0 <br />Fill pipe diameter in inches: <br />4.0 <br />Stage I vapor recovery: <br />DUAL <br />Stage II vapor recovery: <br />ASSIST <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />NOT NOT <br />TESTED TESTED <br />Maienar <br />DW FIBERG <br />Diameter (in): <br />2.0 <br />Length (ft): <br />70.0 <br />Test psi: <br />50 <br />Bleedback cc. <br />95 <br />Test time (min): <br />30 <br />Test 1: Start time: <br />12:40 <br />Finish psi: <br />so NOT NOT <br />Vol change cc: <br />0 <br />Test 2: Start time: <br />12: so TESTED TESTED <br />Finish psi: <br />so <br />Vol change cc: <br />0 <br />Test 3: Start time: <br />13: 00 <br />Finish psi: <br />so <br />Vol change cc: <br />0 <br />Final gph: <br />0.000 <br />Result: <br />PASS <br />Pump type: <br />PRESSURE <br />Pump make: <br />FE PETRO <br />COMMENTS <br />Impact Valves Operational: yES <br />NOT <br />TESTED <br />Printed 03/13/2001 08:20 CCHAPA <br />