My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1985 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
COMPLIANCE INFO 1985 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2023 11:49:43 AM
Creation date
8/26/2019 9:14:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985 - 2004
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
507
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
California Edition: September 1997 <br />Veeder-Root <br />TLS -250, TLS 250i Plus, ILS 250, TLS -300C / 300i / 30OPC , ILS 350, TLS -350 / 350 PC / 350R / 35ORPC <br />Interstitial Liquid Sensor for Steel Tanks (0794390-420) <br />LIQUID -PHASE INTERSTITIAL DETECTOR <br />Detector: <br />Output type: qualitative <br />Sampling frequency: continuous <br />Operating principle: float switch <br />Test Results: <br />TLS -250, TLS 250i Plus, ILS 250, at a flow rate of 0.13 gal/hr in 4.8 cm diameter test chamber <br />** ILS 350, TLS -350, at a flow rate of 0.12 gal/hr in 4.8 cm diameter test chamber. <br />Specificity Results: <br />Activated: diesel fuel, synthetic fuel, heating oil #2, water. <br />Comments: <br />EPA and many states require detection of 1/8 inch (0.32 cm) of product for groundwater monitoring. <br />Test procedures used were Carnegie Mellon Research Institute's "Test Procedures for Third Party <br />Evaluation of Leak Detection Methods: Point Sensor Liquid Contact Leak Detection Systems": Final Report - <br />November 11, 1991. <br />Detector is reusable. <br />Veeder-Root Evaluator: Carnegie Mellon Research Institute <br />125 Powder Forest Dr. Tel: (412) 268-3495 <br />Simsbury, CT 06070-2003 <br />Tel: (203) 651-2700 Date of Evaluation: 07/17/92 <br />291 <br />Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of <br />the method or equipment. Equipment should be installed and operated in accordance with all applicable laws and regulations. <br />unleaded <br />synthetic <br />ag_soline <br />clasoline <br />Accuracy (%) <br />100 <br />100 <br />Response time (min) <br />6.00 <br />6.51 <br />Recovery time (min) <br /><1 <br /><1 <br />Product activation height (cm) <br />3.67 <br />3.62 <br />Lower detection limit (cm) <br />4.05 <br />4.17 <br />TLS -250, TLS 250i Plus, ILS 250, at a flow rate of 0.13 gal/hr in 4.8 cm diameter test chamber <br />** ILS 350, TLS -350, at a flow rate of 0.12 gal/hr in 4.8 cm diameter test chamber. <br />Specificity Results: <br />Activated: diesel fuel, synthetic fuel, heating oil #2, water. <br />Comments: <br />EPA and many states require detection of 1/8 inch (0.32 cm) of product for groundwater monitoring. <br />Test procedures used were Carnegie Mellon Research Institute's "Test Procedures for Third Party <br />Evaluation of Leak Detection Methods: Point Sensor Liquid Contact Leak Detection Systems": Final Report - <br />November 11, 1991. <br />Detector is reusable. <br />Veeder-Root Evaluator: Carnegie Mellon Research Institute <br />125 Powder Forest Dr. Tel: (412) 268-3495 <br />Simsbury, CT 06070-2003 <br />Tel: (203) 651-2700 Date of Evaluation: 07/17/92 <br />291 <br />Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of <br />the method or equipment. Equipment should be installed and operated in accordance with all applicable laws and regulations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.