Laserfiche WebLink
INDIVIDUAL TANK/LINE/LEAK DETECTOR TEST REPORT <br />TANKNOLOGY-NDE <br />TEST DATE: 04/09/97 <br />WORK ORDER NUMBER: 2201012 <br />CLIENT: SHELL PRODUCTS <br />SITE:SHELL 204-7524-2804 <br />TANK INFORMATION -:i. � <br />• <br />Tank ID: <br />1 Material: DW FIBERG <br />Bottom to top fill in inches: 175.0 <br />Product: PREMIUM <br />Tank manifolded: NO <br />Bottom to grade fill in inches: 183.0 <br />Capacity in gallons: 14,976 <br />Vent manifolded: NO <br />Fill pipe length in inches: 55.0 <br />Diameter in inches: 120.00 <br />Vapor recovery manifolded: YES <br />Fill pipe diameter in inches: 4.0 <br />Length in inches: 277 <br />Impact Valves Operational: Y <br />Stage I vapor recovery: DUAL <br />Tank age (years): <br />Overfill protection: <br />Stage II vapor recovery: ASSIST <br />Fuel pure rating: <br />Overspill protection: <br />Installed: <br />COMMENTS <br />TANK TEST RESULTS Jest `Method _VPLTj � <br />LEAK,DETECTQR "ESULT <br />,,T0M'mothod:g ,•: '. � � d <br />PSI at tank bottom: <br />New/passed Failed/replaced New/passed Failed/replaced <br />Fluid level in inches: <br />L.D. #1 <br />L.D. #1 L.D. #2 L.D. #2 <br />UFT/OFT: <br />Make: VEEDERROOT <br />Fluid volume in gallons: <br />Model: <br />Tank water level in inches: <br />S/N; N/A <br />Test time: <br />Open time in sec: <br />Number of thermisters: <br />Holding psi: <br />Specific gravity: <br />Resiliancy cc: <br />Water table depth in inches: <br />Test leak rate ml/m: <br />Determined by (method): <br />Metering psi: <br />Leak rate in gph: <br />Calib. leak in gph: 3.00 <br />Result: <br />Results: <br />PASS <br />COMMENTS <br />COMMENTS <br />V/R ELECTRONIC PLLD. <br />ULLAGE TEST RESULTSTest Method: UTS-4T <br />LINE TEST RESULTS <br />Test tYPe: PTx-sS <br />Test time: <br />Material: DW FIBERG <br />Ullage volume: <br />Diameter (in): 2.0 <br />Ullage pressure: <br />Length (ft): 70.0 <br />Results: <br />Test psi: 50 <br />Bleedback cc: 55 <br />Test time (min): 30 <br />DATA FOR UTS-4T ONLY: <br />Test 1: Start time: 10:00 <br />Time of test 1: <br />Finish psi: 48 <br />Temperature: <br />Vol change cc: 9 <br />Test 2: Start time: 10:10 <br />Flow rate (cfh): <br />Finish psi: 50 <br />Time of test 2- <br />Vol change cc: 0 <br />Test 3: Start time: 10:20 <br />Temperature: <br />Finish psi: 50 <br />Flow rate (cfh): <br />Vol change cc: 0 <br />Time of test 3: <br />Final gph: 0.005 <br />Temperature: <br />Result: PASS <br />Flow rate (cfh): <br />Pump type: PRESSURE <br />COMMENTS <br />Pump make: FE PETRO <br />COMMENTS <br />Printed 10/24/97 13:49 MSHAW <br />8900 SHOAL CREEK, BUILDING 200, AUSTIN, TEXAS 78757 (512) 451-6334 <br />