Laserfiche WebLink
INDIVIDUA' TANK/LINE/LEAK DETECTOR TE-- REPORT NDE <br />NDE EI„VIRONMENTAL CORPOr,HTION <br />TEST DATE: March 23, 1994 <br />CLIENT: SHELL OIL COMPANY <br />WORK ORDER NUMBER: 962320 <br />SITE: SHELL 204-7524-2804 <br />TANK TEST RESULTS I I LEAK DETECTOR RESULTS I <br />Test method: <br />Psi at tank bottom: <br />Fuel level in inches: <br />UFT/OFT- <br />Fuel volume in gallons: <br />Water level in inches: <br />Test time: <br />Number of thermisters: <br />Specific gravity: <br />Water table depth in inches: <br />Determined by (method): <br />Leak rate in gph: <br />RESULT: <br />COMMENTS <br />I ULLAGE TEST RESULTS I <br />Test method: <br />Test time: <br />Ullage volume: <br />Ullage pressure: <br />RESULT - <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: <br />Flow rate: <br />Time of test 2: <br />Temperature: <br />Flow rate: <br />Time of test 3: <br />Temperature: <br />Flow rate: <br />COMMENTS <br />New/passed Failed/replaced <br />detector detector <br />Test method: <br />TANK INFORMATION <br />Tank ID: #1 <br />Product: PLUS <br />Capacity in gallons: 7,050 <br />Diameter in inches: 93.00 <br />Length in inches: 243 <br />- - -- ---- <br />Bottom to top fill in inches: <br />Bottom to grade fill in inches: <br />Fill pipe length in inches: <br />Fill pipe diameter in inches: <br />Stage I vapor recovery: DUAL <br />Material: Tank: STEEL <br />Stage II vapor recovery: BALANCE <br />Manifolded Vent: <br />208931327 <br />V/R: <br />3.00 <br />Holding psi: <br />COMMENTS <br />Resiliency cc: <br />I <br />Test leak rate ml/h: <br />189.0 <br />TANK TEST RESULTS I I LEAK DETECTOR RESULTS I <br />Test method: <br />Psi at tank bottom: <br />Fuel level in inches: <br />UFT/OFT- <br />Fuel volume in gallons: <br />Water level in inches: <br />Test time: <br />Number of thermisters: <br />Specific gravity: <br />Water table depth in inches: <br />Determined by (method): <br />Leak rate in gph: <br />RESULT: <br />COMMENTS <br />I ULLAGE TEST RESULTS I <br />Test method: <br />Test time: <br />Ullage volume: <br />Ullage pressure: <br />RESULT - <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: <br />Flow rate: <br />Time of test 2: <br />Temperature: <br />Flow rate: <br />Time of test 3: <br />Temperature: <br />Flow rate: <br />COMMENTS <br />New/passed Failed/replaced <br />detector detector <br />Test method: <br />FTA <br />Make: <br />RED JACKET <br />Model: <br />X.L.P. <br />S/N: <br />208931327 <br />Open time in sec: <br />3.00 <br />Holding psi: <br />13 <br />Resiliency cc: <br />340 <br />Test leak rate ml/h: <br />189.0 <br />Metering psi: <br />10 <br />Calib. leak in gph: <br />3.00 <br />RESULT: <br />PASS <br />vol change cc: <br />COMMENTS <br />Test 3: start time: <br />22:16 <br />LINE TEST RESULTS <br />Material: STEEL <br />Diameter (in): <br />2.0 <br />Length (in): <br />80.0 <br />Test psi: <br />50 <br />Bleedback cc: <br />0 <br />Test start time <br />30 <br />Test 1: start time: <br />21:56 <br />finish psi: <br />d9 <br />vol change cc: <br />4 <br />Test 2: start time: <br />22:06 <br />finish psi: <br />50 <br />vol change cc: <br />o <br />Test 3: start time: <br />22:16 <br />finish psi: <br />5o <br />vol change cc: <br />o <br />Final gph: <br />0.002 <br />RESULT. <br />PASS <br />Test type: PTK-88 <br />Pump type: PRESSURE Pump make: RED JACKET <br />20000 MARINER AVENUE, SUITE 500, TORRANCE. CALIFORNIA 90503 (31 <br />