Laserfiche WebLink
INDIVIDUA' TANK/LINE/LEAK DETECTOR TE' REPORT NDE <br />NDE EI.,JIRONMENTAL CORPOt ,,-TION . <br />TEST DATE: March 23, 1994 <br />CLIENT: SHELL OIL COMPANY <br />WORK ORDER NUMBER: 962320 <br />SITE: SHELL 204-7524-2804 <br />TANK TEST RESULTS <br />Test method: <br />TANK INFORMATION <br />Psi at tank bottom: <br />Tank ID: <br />Product: <br />#3 <br />REG UNLEAD <br />Bottom to top fill in inches: <br />Bottom to grade fill in inches: <br />136.0 <br />142.0 <br />Capacity in gallons: <br />5,050 <br />Fill pipe length in inches: <br />43.0 <br />Diameter in inches: <br />93.00 <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: <br />174 <br />Stage I vapor recovery: <br />DUAL <br />Material: <br />Tank: <br />STEEL <br />YES <br />Stage II vapor recovery: <br />BALANCE <br />Manifolded Vent: <br />NO <br />PASS <br />V/R: <br />NO <br />COMMENTS <br />I <br />TANK TEST RESULTS <br />Test method: <br />VPLT <br />Psi at tank bottom: <br />1.62 <br />Fuel level in inches: <br />61.00 <br />UFT/OFT: <br />UFT <br />Fuel volume in gallons: <br />3,511 <br />Water level in inches: <br />0.00 <br />Test time: <br />20:48-00:52 <br />Number of thermisters: <br />5 <br />Specific gravity: <br />0.735 <br />Water table depth in inches: <br />Determined by (method): <br />NO WELL <br />Leak rate in gph: <br />0.000 <br />RESULT: <br />PASS <br />COMMENTS <br />NOTE THAT THERE IS NO TYPE OF WELL @ <br />THIS STATION. <br />I ULLAGE TEST RESULTS I <br />Test method: <br />UTS-4 SYSTEM <br />Test time: <br />01:33-02:03 <br />Ullage volume: <br />1,539 <br />Ullage pressure: <br />2.50 <br />RESULT: <br />PASS <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: <br />Flow rate: <br />Time of test 2: <br />Temperature: <br />Flow rate: <br />Time of test 3: <br />Temperature: <br />Flow rate: <br />01:33-01:43 <br />62.60 <br />0.200-0.200 <br />01:43-01:53 <br />62.50 <br />0.200-0.100 <br />01:53-02:03 <br />62.60 <br />0.200-0.100 <br />COMMENTS <br />20000 MARINER AVE <br />Material: <br />Diameter (in): <br />Length (in): <br />Test psi: <br />Bleedback cc: <br />Test start time <br />Test 1: start time: <br />finish psi: <br />vol change cc: <br />Test 2: start time: <br />finish psi: <br />vol change cc: <br />Test 3: start time: <br />finish psi: <br />vol change cc: <br />Final gph: <br />RESULT: <br />LEAK DETECTOR RESULTS <br />New/passed Failed/replaced <br />detector detector <br />Test method: <br />Make: <br />Model: <br />S/N: <br />Open time in sec: <br />Holding psi: <br />Resiliency cc: <br />Test leak rate ml/h: <br />Metering psi: <br />Calib. leak in gph: <br />RESULT: <br />COMMENTS <br />LINE TEST RESULTS <br />Test type: <br />Pump type: NONE <br />COM <br />TE 500, TORRANCE. CALIFORNIA 90503 <br />Pump make: <br />542-4342 <br />