COMPLIANCE INFO 1985 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
COMPLIANCE INFO 1985 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2023 11:49:43 AM
Creation date
8/26/2019 9:14:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985 - 2004
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
507
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
//unTeR <br />leak lokator. <br />LD <br />7- <br />ENVIRONMENTALSERVXXSI INS <br />115 DEWALT AVENUE, N. W. <br />SUITE 400 <br />CANTON, OH 44702 <br />216-453-1800 800-523-4370 <br />TEST <br />z RESULTS <br /># <br />APPLIED <br />DATE OF TEST <br />PRODUCT <br />LOSS <br />CC'S <br />CONTRACT NUMBER <br />CONCLUSION/ <br />RESULT <br />CUSTOMER <br />PRODUCT <br />REMOTE <br />SUCTION <br />LOCATION — IDENTIFICATION NUMBER <br />CC/DIV CC/MIN <br />NAME <br />CC/MIN GPH <br />TEST <br />START <br />ADDRESS <br />CITY <br />STATE <br />TEST RESULTS SUMMARY <br />LEAK LOKATOR USE <br />ONLY <br />SYSTEM <br />TANK SIZE <br />WATER <br />INCHES <br />LEAK LOKATOR RESULTS" <br />CONCL. CODE <br />PRODUCT <br />GALLONS <br />DIA/MATE <br />NCHes <br />AL <br />GPH <br />CONCLUSION <br />RECOMMENDATIONS <br />TEST TANK SYS <br />NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br />OTHER CONTRACTORS, OFFICIALS, CUSTOMER REPRESENTATIVES PRESENT <br />OTHER INFORMATION <br />PRODUCT LINES — HYDROSTATIC PRESSURE TEST RESULTS <br />SYSTEM <br />TYPE OF PUMP <br /># <br />APPLIED <br />MINUTES <br />APPLIED <br />PRODUCT <br />LOSS <br />CC'S <br />PRODUCT <br />LOSS <br />GPH <br />CONCLUSION/ <br />RESULT <br />NO. <br />PRODUCT <br />REMOTE <br />SUCTION <br />CLOCK DURATION <br />(INCHES) <br />HRS. -MIN. <br />CC/DIV CC/MIN <br />Q 'F CC/MIN <br />CC/MIN GPH <br />TEST <br />START <br />NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br />OTHER CONTRACTORS, OFFICIALS, CUSTOMER REPRESENTATIVES PRESENT <br />DETAIL OF TEST RESULTS <br />LEVEL — INCHES FROM TANK BOTTOM TO TEST LEVEL <br />ALR — ABSOLUTE LEAK RATE (MEASURED LEAK RATE — TEMPERATURE COMPENSATION) IN GALLONS PER HOUR <br />CONCLUSION — NFPA 329 CRITERION OF ±0.05 GPH IS USED TO CERTIFY TIGHTNESS <br />CERTIFICATION This is to certify that the above described tank systems were tested, using the HUNTER ENVIRONMENTAL <br />SERVICES, INC. LEAK LOKATOR according to all standard operating procedures. Those indicated as tight at full <br />system meet the criterion established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br />Y EM <br />TEST <br />TESTTIME <br />LEVEL <br />LEAK RATE <br />COMPENSATION <br />LEAK RATE <br />CHET <br />NO. <br />NAME <br />NO. <br />CLOCK DURATION <br />(INCHES) <br />HRS. -MIN. <br />CC/DIV CC/MIN <br />Q 'F CC/MIN <br />CC/MIN GPH <br />TEST <br />START <br />LEVEL — INCHES FROM TANK BOTTOM TO TEST LEVEL <br />ALR — ABSOLUTE LEAK RATE (MEASURED LEAK RATE — TEMPERATURE COMPENSATION) IN GALLONS PER HOUR <br />CONCLUSION — NFPA 329 CRITERION OF ±0.05 GPH IS USED TO CERTIFY TIGHTNESS <br />CERTIFICATION This is to certify that the above described tank systems were tested, using the HUNTER ENVIRONMENTAL <br />SERVICES, INC. LEAK LOKATOR according to all standard operating procedures. Those indicated as tight at full <br />system meet the criterion established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br />TESTS CONDUCTED BY <br />CERTIFIED BY <br />TEST VAN NO. <br />TANK TESTING SPECIALIST <br />SIGNATURE <br />GATE <br />TANK TESTING SPECIALIST <br />NAME <br />TITLE <br />
The URL can be used to link to this page
Your browser does not support the video tag.