EHD Program Facility Records by Street Name
>
C
>
CARPENTER
>
4863
>
2800 - Aboveground Petroleum Storage Program
>
PR0538368
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/9/2019 1:17:50 PM
Creation date
8/26/2019 11:12:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0538368
PE
2832
FACILITY_ID
FA0005712
FACILITY_NAME
SGS Stockton - Carpenter Road
STREET_NUMBER
4863
STREET_NAME
CARPENTER
STREET_TYPE
RD
City
Stockton
Zip
95215
APN
17905010
CURRENT_STATUS
01
SITE_LOCATION
4863 CARPENTER RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S b N J 0 A Q U I N Environmental Health Department <br /> COUNTY— <br /> Aboveground <br /> CUNTYAboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SGS Stockton-Carpenter Road 4863 CARPENTER RD, Stockton August 21, 2019 <br /> Other Violations <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandon ment/lIlegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 301 CFR 112.5(a) Failed to amend Plan as necessary. <br /> The 275 gallon new oil tank,400 gallon used oil tank, new/used oil drums and 125 gallon mobile refueler were <br /> removed from the facility approximately 18 months ago per Tony Ruff(Unit Supervisor). These tanks are still <br /> included in the SPCC plan on page 3. The Spill Prevention, Control, and Countermeasure(SPCC) Plan must be <br /> amended when there is a change in the facility design, construction, operation, or maintenance that materially affects <br /> its potential for a discharge,within 6 months of the change, and implemented as soon as possible, not later than 6 <br /> months following preparation of the amendment. Immediately ensure that the SPCC Plan accurately represents the <br /> procedures and policies currently in place at the facility and submit proof to the EHD. <br /> This is a minor violation. <br /> 711 CFR 112.8(c)(6)Failed to perform scheduled tank tests or inspections by appropriately qualified personnel. <br /> The 240 gallon diesel tank was not inspected annually. No annual inspection records were available for review <br /> during the inspection. Page 9 of the SPCC plan states that annual inspections will be done on steel tanks. Each <br /> aboveground container shall be tested and inspected for integrity on a regular schedule and whenever repairs are <br /> made. The qualifications of personnel performing tests and inspections,frequency and type of testing and <br /> inspections that take into account container size, configuration, and design shall be determined in accordance with <br /> industry standards. Examples of these integrity tests include, but are not limited to: visual inspection, hydrostatic <br /> testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other systems of non-destructive <br /> testing. Comparison records and other records of inspections and tests must be maintained on site. Immediately <br /> conduct the annual inspection and submit a copy to the EHD, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a repeat violation, Class II. <br /> 715 CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation. <br /> Liquid level sensing devices have not been tested for the 240 gallon gasoline tank. The plastic level indicator of the <br /> gauge was off the tank and in the secondary containment. Liquid level sensing devices must be installed in <br /> accordance with CFR 112.8 and shall be regularly tested to ensure proper operation. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> FA0005712 PR0538368 SCO01 08/21/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 4 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.