Laserfiche WebLink
Wright <br /> Environmental <br /> Services, Inc. <br /> Construction ♦ Engineering ♦ Remediation <br /> December 14, 2007 <br /> Protect No 4090-P Co <br /> Ms Janke Brown ' <br /> Go Cox & Cox <br /> 1593 Arrowhead Drive �. <br /> St Helena, California 94574 = '= <br /> n? m F; <br /> Re Cox & Cox, Quarterly Monitoring Well Sampling Report N ` <br /> Site at 595 East 11th Street, Tracy, CA w <br /> Dear Ms Brown, <br /> Wright Environmental Services, Inc (Wright) has prepared this quarterly report for the <br /> above referenced site As you know, several phases of work have been performed at this site <br /> This work is in response to a request from the San Joaquin County Public Health Services (PHS <br /> EHD) for site monitoring <br /> Monitoring Well Sampling Methods <br /> The site was sampled on November 16, 2001 The attached table lists the wells historic and <br /> current groundwater level data (see Table 1) The sampler proceeded to purge well volumes of <br /> .� groundwater using a submersible electric purging pump (a volume calculation was done for <br /> each well following sounding measurements) Conductivity, pH, and water temperature readings <br /> were obtained between each well volume purge, and these were noted on the attached <br /> groundwater sampling information sheets Once these readings stabilized after two consecutive <br /> purge volumes, aquifer water is assumed to be entering the well When the well recovered to <br /> about 80% of the initial water level, the sample was collected Purge water was stored on-site <br /> in drums The well sampling information sheets are attached <br /> The groundwater sample was collected with a new disposable bailer The groundwater sample <br /> was then poured with minimum cavitation into the appropriate, laboratory prepared sample <br /> containers leaving no headspace The sample container was then immediately capped, labeled <br /> under chain-of-custody documentation and placed in a chilled ice chest for shipment to <br /> Chromalab, Inc in Pleasanton, California (a State Certified Testing Lab) <br /> Groundwater Contour Map and Flow Gradient <br /> A groundwater contour map to a known datum was prepared for the data listed in Table 1 (see <br /> Figure 1) The groundwater flow direction was northerly under a calculated gradient of 0 0024, <br /> which is consistent with historic observed trends Overall groundwater levels appear to have <br /> fallen slightly from the previous quarter Groundwater levels in wells MW-3 and MW-9 were <br /> not used in contouring as the field measurements were interpreted as anomalous compared to the <br /> rest of the site <br /> 0 <br /> 67 E 10th Street • Tracy,CA 95376 <br /> 209 833 0758 • Fax 209 832 5152 <br /> wnght@inreach com Lic #651501 A-B HazMat Page 1 A <br /> websit hap 11home rnreach com/wright i� <br />