My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0010074
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
595
>
3500 - Local Oversight Program
>
PR0544793
>
ARCHIVED REPORTS XR0010074
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:03 AM
Creation date
9/3/2019 1:28:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0010074
RECORD_ID
PR0544793
PE
3528
FACILITY_ID
FA0006237
FACILITY_NAME
HONEST AUTO SALE AND REPAIR
STREET_NUMBER
595
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23337004
CURRENT_STATUS
02
SITE_LOCATION
595 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'" "" Wright <br /> �4 �T Environmental <br /> Services, Inc. , <br /> ,. ar <br /> August 17, 2001 Canstruct:on ♦ Engineering • Remediationif� <br /> Project No 4090-P 9, <br /> f� <br /> Ms Janice Brown <br /> c/o Cox & Cox <br /> 1593 Arrowhead Drive <br /> St Helena, California 94574 <br /> Re, Cox & Cox, Quarterly Monitoring Well Sampling Report <br /> Site at 595 East 11th Street, Tracy, CA <br /> Dear Ms Brown, <br /> Wright Environmental Services, Inc (Wright) has prepared this quarterly report for the <br /> above referenced site As you know, several phases of work have been performed at this site <br /> This work is in response to a request from the San Joaquin County Public Health Services (PHS <br /> EHD) for site monitoring <br /> Monitoring Well Sampling Methods <br /> The site was sampled on July 30, 2001 The attached table lists the wells historic and current <br /> groundwater level data (see Table 1) The sampler proceeded to purge well volumes of <br /> groundwater using a submersible electric purging pump (a volume calculation was done for <br /> each well following sounding measurements) Conductivity, pH, and water temperature readings <br /> were obtained between each well volume purge, and these were noted on the attached <br /> groundwater sampling information sheets Once these readings stabilized after two consecutive <br /> purge volumes, aquifer water is assumed to be entering the well When the well recovered to <br /> about 80% of the initial water level, the sample was collected Purge water was stored on-site <br /> in drums The well sampling information sheets are attached <br /> The groundwater sample was collected with a new disposable bailer The groundwater sample <br /> was then poured with minimum cavitation into the appropriate, laboratory prepared sample <br /> containers leaving no headspace The sample container was then immediately capped, labeled <br /> under chain-of-custody documentation and placed in a chilled ice chest for shipment to <br /> Chromalab, Inc in Pleasanton, California (a State Certified Testing Lab) <br /> Groundwater Contour Map and Flow Gradient <br /> A groundwater contour map to a known datum was prepared for the data listed in Table 1 (see <br /> Figure 1) The groundwater flow direction was northerly under a calculated gradient of 0 0038, <br /> which is consistent with historic observed trends Overall groundwater levels appear to have <br /> fallen slightly from the previous quarter <br /> 67 E 10th Street . Tracy,CA 95376 <br /> 209 833 0758 • Fax 209 832 5152 <br /> wright@enreach com Lic #651501 A-B HaWat page 1 i4, <br /> websit hap 11home inreaeh comfwright <br />
The URL can be used to link to this page
Your browser does not support the video tag.