Laserfiche WebLink
0 <br /> STable 1. Monitoring Well Water Levels, con't. <br /> Well Date Well Depth to Casing Water Floating <br /> No Sampled Depth Water Elev Elev Product <br /> (ft) (ft) (MSL ft)* (MSL ft) <br /> MW-3 9114195 16 28 765 47 94 40 29 None <br /> M W-3 3/28196 1615 690 ----- 41 04 None <br /> MW-3 6127/96 16 10 737 ----- 41 57 None <br /> MW-3 12/19/96 1610 725 ----- 40 69 None <br /> MW-3 3/10/97 1610 716 ----- 40 78 None <br /> MW-3 6130/97 1610 764 ----- 40 32 None <br /> MW-3 8120197 1610 790 ----- 40 04 None <br /> MW-3 12/12/97 1610 750 ----- 40 44 None <br /> MW-3 3131/98 1622 621 ----- 41 73 Nene <br /> MW-4^ 8/20197 16 45 821 47 60 39 39 None <br /> MW-4^ 12/12/97 16 45 773 ----- 39 87 None <br /> MW-4^ 3/31198 16 45 700 ----- 40 60 None <br /> MW-5^ 8/20197 -16 95 820 47 79 39 59 None <br /> MW-5^ 12/12/97 16 95 7 75 ----- 40 04 None <br /> MW-5^ 3/31/98 16 91 7 15 ----- 40 64 None <br /> MW-6^ 8120197 17 45 822 48 92 40 70 None <br /> MW-6^ 12/12/97 17 45 7 85 41 07 None <br /> MW-6^ 3/31/98 17 05 715 ----- 41 77 None <br /> MW-7^ 8120/97 14 95 7 82 48 78 40 96 Norte <br /> MW-7^ 12/12/97 14 95 Z 7 84 ----- 40 94 None <br /> MW-7^ 3/31/98 13 04 v 708 ----- 41 67 None <br /> MW-8^ 8/20197 16 00 7 96 47 90 39 94 None <br /> MW-8^ 12/12/97 16 00 Z 7 57 ----- 40 33 None <br /> MW-8^ 3/31/98 14 56 1 6 79 ----- 41 11 None <br /> MW-9^ 8120/97 15 95 833 48 28 39 95 None <br /> MW-9^ 12/12/97 15 95 8 00 ..... 40 28 None <br /> MW-9^ 3131198 13 18 723 ----- 41 05 None <br /> * Casing elevation data from Evax Technologies, Site Investigation Report, April 7, 1992 <br /> ^ Casing elevation data from Triple "E" Engineering and Surveying, August 14, 1997 <br /> The sampler proceeded to purge well volumes of groundwater using a submersible electric <br /> purging pump (a volume calculation was done for each well following sounding measurements) <br /> Between each well volume purge, conductivity, pH, and water temperature readings were <br /> obtained and noted on the attached groundwater sampling information sheets Once these <br /> readings stabilized after two consecutive purge volumes aquifer water is assumed to be entering <br /> the well When the well recovered to about 80% of the initial water level, the sample was <br /> collected Purge water was stored on-site in drums The well sampling information sheets <br /> containing data on temperature, conductivity, pH, depth to water, and well volumes purged are <br /> 101 attached <br /> Page 2 <br />