My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0010013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
612
>
3500 - Local Oversight Program
>
PR0544794
>
ARCHIVED REPORTS XR0010013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:02 AM
Creation date
9/3/2019 2:13:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0010013
RECORD_ID
PR0544794
PE
3528
FACILITY_ID
FA0013337
FACILITY_NAME
SOUZA II LLC (VACANT LOT)
STREET_NUMBER
612
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23439018
CURRENT_STATUS
02
SITE_LOCATION
612 W ELEVENTH ST
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• CHECKLIST OF REQUIRED DATA FOR NO FURTHER ACTION REQUESTS AT <br /> UNDERGROUND TANK SITES <br /> Souza II, LLC, 612 West I Vh Street, Tracy,California <br /> I Distance to production wells within 2,000 feet of the site Up to nine production wells were identified <br /> within 2,000 feet of the site Two wells are active Three wells have been destroyed water supply wells, <br /> and four wells have an unknown status None of the "unknown" wells could be located in the field <br /> during the area reconnaissance, consequently, they are presumed to be destroyed The closest active <br /> production well is approximately 1 155 feet south-south west (upgradient) of the site as depicted on the <br /> (of Figure in Attachment A See the Sensitive Receptor Survey Report(Ground Zero Analysis, Inc, August also <br /> 23,2002)for more details on these wells and others within 2,000 feet of the site V,,,,V% F,_I� r arm <br /> f 5 pGI'i l l'l'c- 54 4.r1.- )is fyp0�'Vnf—not�'iy =,tf Pel� 11 <br /> 2 Site maps Site maps depicting the former UST locations, soil boring locations, monitoring well -}9`V ' <br /> t� loc tans oundwa�er gr�dients buildings and streets are included m Attachment A - 00 s bsv r�dW id <br /> Ri n� �a �.��' —s�y 'No mW efcvzi a� cawnto"rs u+,l,fles <br /> �how„ D <br /> 4 �k ,51A Cross sections and figures picting lithology Soil boring logs, monitoring well logs and cross sections <br /> included in Attachment B depict the stratigraphy of the site h OAP— 11sfi,,,k <br /> 4 Stockpiled soil No contaminated soil generated from the tank excavation or drilling activities remains <br /> on site Soil that was documented as ND through laboratory analyses was utilized on site as fill Soil <br /> with detectable concentrations of petroleum hydrocarbons was reToved and disposed of at a Class 2 <br /> landfill -;-J!i t s i q -4- 13 <br /> 5 Monitoring wells remaining on site fate Three monitoring wells remain at the site (MW I, MW2, <br /> MW3) It is recommended that these wells be properly destroyed by backfilling with grout to the ground <br /> surface once site closure is granted <br /> 6 Tabulated results of RToundwater elevations and depths to water A table of groundwater elevation data <br /> is included in Attachment C Depths to water at the site have ranged from approximately 10 82 feet <br /> below grade to 12 31 feet below grade <br /> 7 Tabulated results of all sampling and analyses, including detection limits for confirmation sampling and <br /> lead analyses Analytical data for all soil and groundwater samples are summarized in the tables <br /> included in Attachment C <br /> 8 Concentration contours of contaminants in soil and groundwater <br /> Attachment D includes figures depicting 1)the lateral extent of soil contamination between the depths of <br /> approximately 10-15 feet,2)Cross sections showing the estimate vertical extent of soil contamination, 3) <br /> a figure showing the estimated lateral extent of groundwater contamination <br /> 9 Zone of influence for remediation system Not applicable <br />
The URL can be used to link to this page
Your browser does not support the video tag.