Laserfiche WebLink
� zZ <br /> SERVICES, INCORPORATED <br /> � aon <br /> MPDS-UN0788-10 <br /> June 2, 1997 <br /> y Tosco Distibution Company <br /> P.O.Box 25376 <br /> Santa Ana, California 92799-5376 <br /> Attention: Mr. Dan Truzzolino <br /> RE: Semi-Annual Data Report <br /> Tosco (Former Unocal) Bulk Plant #0788 <br /> 8203 East 11th Street <br /> Tracy_, California <br /> Dear Mr. Truzzolino: <br /> This data report presents the results of the most recent monitoring and sampling of the monitoring <br /> wells at the referenced site by MPDS Services, Inc. <br /> RECENT FIELD ACTIVITIES <br /> The monitoring wells that were monitored and sampled are indicated in Table 1. Prior to sampling, <br /> the wells were checked for depth to water and the presence of free product or sheen. The monitoring <br /> data and the ground water elevations are summarized in Table 1. The ground water flow direction <br /> during the most recent semi-annual period is shown on the attached Figure 1. <br /> Ground water samples were collected on May 6, 1997. Prior to sampling, the wells were each purged <br /> of between 5 and 21.5 gallons of water. During purging operations, the field parameters pH, tempera- <br /> ture, and electrical conductivity were recorded on the purging/sampling data sheets which are attached <br /> to this report. Once the field parameters were observed to stabilize, and where possible, a minimum <br /> of approximately three casing volumes had been removed from each well, samples were then collected <br /> using a clean Teflon bailer. The samples were decanted into clean VOA vials and/or one-liter amber <br /> bottles, as appropriate, which were then sealed with Teflon-lined screw caps, labeled, and stored in <br /> a cooler, on ice, until delivery to a state-certified laboratory. MPDS Services, Inc. transported the <br /> purged ground water to the Tosco Refinery located in Rodeo, California, for treatment and discharge <br /> to San Pablo Bay under NPDES permit. <br /> ANALYTICAL RESULTS <br /> The ground water samples were analyzed at Sequoia Analytical Laboratory and were accompanied by <br /> properly executed Chain of Custody documentation. The analytical results of the ground water <br /> samples collected to date are summarized in Table 2. The concentrations of Total Petroleum <br /> Hydrocarbons (TPH) as gasoline, TPH as diesel, and benzene detected in the ground water samples <br /> collected during this semi-annual period are shown on the attached Figure 2. Copies of the laboratory <br /> analytical results and the Chain of Custody documentation are attached to this report. <br /> 2401 Stanwell Drive,Suite 400,Concord, CA 94520 <br /> TEL-: (510)602-5120 FAX: (510) 689-191a <br />