SU0004857 SSCRPT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ARNAUDO
>
175
>
2600 - Land Use Program
>
PA-0400737
>
SU0004857 SSCRPT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2019 2:52:56 PM
Creation date
9/4/2019 9:55:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSCRPT
RECORD_ID
SU0004857
PE
2611
FACILITY_NAME
PA-0400737
STREET_NUMBER
175
Direction
W
STREET_NAME
ARNAUDO
STREET_TYPE
BLVD
City
MOUNTAIN HOUSE
APN
NUMEROUS
ENTERED_DATE
2/22/2005 12:00:00 AM
SITE_LOCATION
175 W ARNAUDO BLVD
RECEIVED_DATE
2/22/2005 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\A\ARNAUDO\175\PA-0400737\SU0004857\SSC RPT.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Construction-Site Plan Review Program <br /> ` The Department of Conservation's Division of Oil, Gas, and Geothermal Resources(Division)is charged with <br /> implementing Section 3208.1 of the Public Resources Code(PRC).As a result,the Division developed the <br /> Construction-Site Plan Review Program to assist local permitting agencies in identifying and reviewing the status <br /> of oil or gas wells located near or beneath proposed structures. <br /> Before issuing building or grading permits, local permitting agencies review and implement the Division's <br /> preconstruction well requirements. Interaction between local permitting agencies and the Division helps resolve <br /> land-use issues and allows for responsible development in oil and gas fields. <br /> N. The Division's Construction-Site Plan Review Program consists of the following: <br /> • Procedures for Plugging Construction-Site Wells <br /> • Construction-Site Plan Requirements <br /> o Construction-Site Review Application(PDF) <br /> • Conducting Gas Tests on Wells <br /> r. • Obtaining a Permit to Work on a Well <br /> • What Will You Receive from the Division? <br /> • Contaminated Soil Found at a Construction Site <br /> • Water Wells <br /> Vent Systems and Other Gas Mitigation Measures <br /> • Contacts <br /> • Well Abandonment Contractors(Excel File) <br /> Procedures for Plugging and Abandonment or Reabandonment of Construction-Site Wells <br /> A.The applicant(developer/landowner)presents a construction-site plan to the local permitting agency. <br /> B.The local permitting agency checks the construction-site plan against Division maps to determine if any wells <br /> are located within or adjacent to the indicated property boundaries. If a well appears to be located within this area, <br /> the applicant is directed by the local permitting agency to provide materials specified by the Construction-Site Plan <br /> + Review Program to the Division to initiate the review process. <br /> C.The applicant provides the Division with the pertinent information and the district office provides the applicant <br /> with the well-location and elevation information from well records. <br /> 4 <br /> D.With the provided well location(s),the applicant must locate, uncover,and,when necessary,survey the well(s). <br /> If a well cannot be located using a well-record location description,sufficient efforts, including excavation, must be <br /> made to ascertain each well's location within the construction-site boundaries. <br /> E.The following procedures should be used to locate all wells within the construction site: <br /> _ 1.The applicant must attempt to locate a well using the location of record and dig an excavation that is at least 15 <br /> ` feet long, 15 feet wide,and 6 feet deep.or sufficiently larger or deeper as necessary.The applicant shall notify the <br /> Division to witness all completed excavations before they are back filled. <br /> 2. If the well is not located in Step 1,a magnetometer should be used to survey the area inside and outside of the <br /> excavation. <br /> 3.The applicant may be required to further excavate locations with magnetic anomalies by increasing the size of <br /> the excavation or using a more specialized geophysical survey. <br /> 4. If the well search efforts prove unsuccessful,the applicant must prepare a written report describing the search <br /> procedures and attach the excavation photographs. - <br /> F. All accessible abandoned wells located on a construction site must be tested for gas leakage and <br /> inspected for oil leakage.Any welded steel plates must be removed,and the presence of a competent cement <br /> plug must be verified in the casing and all annular spaces. <br />
The URL can be used to link to this page
Your browser does not support the video tag.