My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0069438
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AVENA
>
21268
>
2600 - Land Use Program
>
SR0069438
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2020 11:52:15 AM
Creation date
9/4/2019 10:07:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SR0069438
PE
4201
STREET_NUMBER
21268
Direction
E
STREET_NAME
AVENA
City
ESCALON
Zip
95320
APN
20523001
ENTERED_DATE
4/15/2014 12:00:00 AM
SITE_LOCATION
21268 E AVENA
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\A\AVENA\21268\PA # UNASSIGNED\LIQUID WASTE PLN CK.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
December 18. 2014 <br /> FOR: Mr. Rodney Estrada, Program Manager <br /> San Joaquin Count), Environmental Health Department <br /> 1868 E. Hazelton Ave. <br /> Stockton, CA 95205 <br /> PROJECT: deVisser Dairy <br /> Proposed Dairy Milk Barn <br /> Septic System Design and Operational Criteria <br /> 21268 East Avena Road <br /> Escalon. California 95320 <br /> Application Number: N/A <br /> (209) 581-1692 <br /> APN: 205-230-01 <br /> SUBJECT: Change in Septic Tank Specification <br /> Reference is made to Chesney Consulting Report Number SSD02.14. On Page 3 of this report,a <br /> monolithic septic tank was specified due to the possibility of traffic, possibly a milk tanker, <br /> driving over this tank. A monolithic tank would offer greater protection than a two-piece tank <br /> from severe loading. <br /> However, the contractor failed to secure a permit from EHD and installed a two-piece tank. If the <br /> contractor had secured the permit from EHD he would have known the tank specification. Now <br /> that the two-piece tank has been installed, it is acceptable for it to remain provided that some <br /> form of protection (railroad ties, bollards, etc.) is placed around the septic system (which <br /> includes the tank and leachfield)to prevent vehicular traffic over the system. <br /> Please contact the undersigned if there should be any questions regarding this correspondence. <br /> Respectfully submitted, <br /> Q1ofessfo <br /> CHESNEY CONSULTING <br /> T4No,75479 <br /> Don Chesnev, PE *s : <br /> Registered Civil Engineer#075479 ivil <br /> c°r Csli(ot <br /> P. O. Box 3794 • TurCock, C-A 95381 • Office (209) 668-1403 • Fax (209) 668-2598 <br />
The URL can be used to link to this page
Your browser does not support the video tag.