My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011936
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
B
>
2820
>
2600 - Land Use Program
>
PA-1800106
>
SU0011936
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:32 AM
Creation date
9/4/2019 10:10:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0011936
PE
2626
FACILITY_NAME
PA-1800106
STREET_NUMBER
2820
Direction
S
STREET_NAME
B
STREET_TYPE
ST
City
STOCKTON
Zip
95206-
APN
17119036, 17119023
ENTERED_DATE
9/14/2018 12:00:00 AM
SITE_LOCATION
2820 S B ST
RECEIVED_DATE
9/11/2018 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
TSok
Supplemental fields
FilePath
\MIGRATIONS\B\B\2820\PA-1800106\SU0011936\APPL.PDF \MIGRATIONS\B\B\2820\PA-1800106\SU0011936\CDD OK.PDF \MIGRATIONS\B\B\2820\PA-1800106\SU0011936\EH COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
111
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(2) If Fire Protection Systems are required they shall be installed according to the CFC, Chapter <br /> 9 and the appropriate standards and guides adopted in Chapter 35 of the California Building <br /> Code and the California Electrical Code. <br /> (3) CFC, Section 503 Fire Apparatus Access Roads — Shall be provided as required by this <br /> section. <br /> (4) CFC, Section 906 Portable Fire Extinguishers — Provide portable fire extinguishers as <br /> required by this section. <br /> (5) CFC, Section 506 Key Box — A Knox® Box shall be installed according to the local fire <br /> department's instructions. Make application for the key box at the fire district having <br /> jurisdiction of this project. If there is an electronically controlled access gate at this site a <br /> Knox®key switch will also be required. <br /> (6) CFC, Section 5001.3.3.1 Properties of Hazardous Materials — A complete list of hazardous <br /> materials used and or stored at this site shall be provided. <br /> (7) A complete review, at building permit submittal, will require compliance with applicable codes <br /> and ordinances. <br /> (8) CFC, Section 105 Permits: Operational permit(s) may be required prior to occupancy. <br /> 2. DEPARTMENT OF PUBLIC WORKS (Staff Contact: Alex Chetley, [209]468-3000) <br /> a. The developer shall provide drainage facilities in accordance with the San Joaquin County <br /> Development Standards. Retention basins shall be fenced with six (6) foot high chain link fence <br /> or equal when the maximum design depth is 18 inches or more. Required retention basin <br /> capacity shall be calculated and submitted along with a drainage plan for review and approval, <br /> prior to release of building permit. (Development Title Section 9-1135) <br /> b. The Traffic Impact Mitigation Fee shall be required for this application. The fee is due and <br /> payable at the time of building permit application. The fee will be based on the current schedule <br /> at the time of payment. The fee shall be automatically adjusted July 1 of each year by the <br /> Engineering Construction Cost Index as published by the Engineering News Record. <br /> (Resolutions R-00-433) <br /> c. The Regional Transportation Impact Fee shall be required for this application. The fee is due and <br /> payable at the time of building permit application. The fee will be based on the current schedule <br /> at the time of payment. (Resolution R-06-38) <br /> d. The Water Supply Facilities Impact Mitigation Fee shall be required for this development. The fee <br /> is due and payable prior to issuance of the building permit. The fee will be based on the current <br /> schedule at the time of payment. (Development Title Section 9-818.4 and Resolutions R-91-327, <br /> R94-185 and R-97-5) <br /> e. A copy of the Final Site Plan shall be submitted prior to release of building permit. <br /> f. This project falls within the definition of a Priority Project as defined in either the County "Storm <br /> Water Quality Control Criteria Plan" (SWQCCP) or the County Phase I National Pollutant <br /> Discharge Elimination System (NPDES) permit and shall comply with the following conditions: <br /> (1) A registered professional engineer shall design a system or combination of systems to treat, <br /> filter, or infiltrate the 85th percentile storm as defined in the County's 2009 SWQCCP. The <br /> San Joaquin County PA-1800106/Progressive Community Church <br /> Community Development Page 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.