CONCLUSIONS AND RECOMMENDATIONS <br /> In summary, the soil conditions near the percolation tests appear to be suitable for use <br /> with on-site septic systems. Satisfactory soil percolation rates of less than 4.5 min/in <br /> (Parcel 1), less than 4.7 min/in (Parcel 2), 7.4 min/in (Parcel,p), and less than 4.8 min/in <br /> (Parcel 4) and were observed in the test locations. No n construction is proposed. <br /> With a satisfactory test, the area 100 feet in radius fro"e test location could be used i <br /> to construct a septic system drain field. <br /> The depth of ground water based on recent aquifer levels is approximately 18 to 22 feet. <br /> The ground-water flow direction is to the north at a rate of approximately seven to 14 <br /> feet per mile in the vicinity of the Site. <br /> No wells are located on the Site, and no water sample was collected for this <br /> investigation. <br /> We believe the Site suitable for development with the use of standard septic systems <br /> utilizing leach lines, leach lines and sumps, or a filter bed. <br /> LOGE 1223 Page 7 <br />