Laserfiche WebLink
April 15, 2015 Lab ID : STK1532998 <br /> Live Oak Geo Environmental Customer : 3-16608 <br /> Quality Control - Inorganic <br /> Constituent Method Date/ID Type Units Colic. QC Data DQO Note <br /> Wet Chem <br /> Nitrate+Nitrite as N 4500NO3F MS mg/L 11.27 94.9% 5-285 <br /> (V11541012-001) MSD mg/L 11.27 96.0% 5-285 <br /> MSRPD mg/L 11.27 1.0% <30.4 <br /> 450ONO3F 04/01/15:204901CJJ ICB mg/L 0.091 0.1 <br /> ICV mg/L 11.27 96.8% 90-110 <br /> CCB mg/L 0.098 0.1 <br /> CCV m L 1 11.27 99.3% 1 90-110 <br /> Definition <br /> ICV :Initial Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> ICB :Initial Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> CCV Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> MS :Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyted.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> MSRPD :MS/MSD Relative Percent Difference(RPD)-The MS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> DQO Data Quality Objective-This is the criteria against which the quality control data is compared. <br /> Page 7 of 7 <br />