My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0004126
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BIRD
>
35656
>
2600 - Land Use Program
>
QX-91-0005
>
SU0004126
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/27/2024 9:08:38 AM
Creation date
9/4/2019 10:27:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0004126
FACILITY_NAME
QX-91-0005
STREET_NUMBER
35656
Direction
S
STREET_NAME
BIRD
STREET_TYPE
RD
City
TRACY
ENTERED_DATE
5/12/2004 12:00:00 AM
SITE_LOCATION
35656 S BIRD RD
RECEIVED_DATE
11/18/1997 12:00:00 AM
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
FilePath
\MIGRATIONS\B\BIRD\35656\QX-91-05\SU0004126\PUB REC REL APPL.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1293
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXPLANATION OF TERMS <br /> BLANK QA/QC - Analyte free sample analyzed to determine if background contamination is present in any instrument or techniques used for analysis. <br /> TYPES <br /> DLR => Detection Limit for Reporting purposes. <br /> MDL => Method Detection Limit. This number represents the smallest non-zero value that FGL can reproduce for a method. The DLR must <br /> be greater than or equal to the MDL. <br /> CALIBRATION QA/QC - Standard analyzed to determine the Accuracy of any instruments and/or techniques used for analysis. <br /> TYPES <br /> ICV -> Independent Calibration Verification standard. Analyzed to check the accuracy of the standard used to calibrate an instrument or technique. <br /> I <br /> CCV => Continuing Calibration Verification standard. Analyzed to check the accuracy of the instrument or technique calibration, ""��i <br /> LCS -> Laboratory Control Standard. Analyzed to check the accuracy of the entire method from prep thru analysis. �J <br /> DLS => Detection Level Standard. Used for verification and determination of MDL. <br /> METHOD QA/QC - Matrix specific samples analyzed to determine accuracy and/or precision of the entire method. <br /> TYPES <br /> Dup => Samples are prepared and analyzed in Duplicate to determine the Precision of the method. The RAD or Relative Percent Difference is calculated and <br /> compared to the MAV for all constituents. <br /> DS => Blank Spike / Blank Spike Duplicate. A Laboratory Blank matrix is Spiked with a known amount of analyte then prepared and analyzed along with a <br /> batch of samples. <br /> j MS => Matrix Spike / Matrix Spike Duplicate. A Client provided matrix is Spiked with a known amount of analyte then prepared and analyzed along with a <br /> batch of samples. <br /> CALCULATIONS <br /> % AEC => Percent Recovery of an analyte introduced (spiked) at a know level (Concentration). % REC should be within the AR. <br /> AR => Acceptance range of the % REC for an analyte. The AR is determined by averaging all % REC data for a specific matrix and then calculating the <br /> 95 % confidence interval. <br /> % DIF => (Relative) Percent Difference of a sample analyzed in duplicate. % DIF should be <= MAV. <br /> MAV => Maximum Acceptance Value for the % DIF of an analyte. The MAV is determined by averaging all % DIF data for a specific matrix and then calculating <br /> the 95 % confidence interval. <br /> Conc. => The theoretical ammount of analyte present in the sample prior to analysis. <br /> • => Indicates a special or modified DLR was applied for the acceptance criteria. <br /> => Indicates the average concentration spiked for MS/MSD or BS/BSD when the concentration spiked was not identical for both QC samples. <br />
The URL can be used to link to this page
Your browser does not support the video tag.