Laserfiche WebLink
ENVIRONMENTAL HEALTH DEPARTMENT <br /> SAN JOAQUIN COUNTY <br /> " Unit Supervisors <br /> Donna K.Heran,R.E.H.S. <br /> 304 East Weber Avenue, Third Floor Carl Borgman,R.E.H.S. <br /> _ Director Mike�Huggins,R.E.H.S.,R.D.I. <br /> •'.� Al Olsen,R.E.H.S. Stockton, California 95202-2708 <br /> Program Manager Douglas W.Wilson,R.E.H.S. <br /> c4;lFotii��P Telephone: (209)468-3420 Margaret Lagorio,R.E.H.S. <br /> Laurie A.Cotulia,R.E.H.S. <br /> Program Manager Fax: (209) 464-0138 Robert McClellon,R.E.H.S. <br /> Mark Barcellos,R.E.H.S. <br /> 17' Ur <br /> June 27, 2002 _. <br /> TO: San Joaquin County i; JUL 012002 <br /> Community p p Development Department <br /> Community Development uct,t. <br /> FROM: San Joaquin County <br /> Environmental Health Department <br /> CONTACT PERSON: Raymond Borges,Lead Senior R.E.H.S., R.D.I. <br /> PHONE NUMBER: 209 468-3284 <br /> RE: PA-02-237(SA),Attention: Jennifer Jolley <br /> 2900 North Bozzano Road (Private Road), Stockton <br /> The San Joaquin County Development Title Requirements listed below have been identified as <br /> pertinent to this project. Other requirements may also apply. These requirements cannot be <br /> modified. <br /> A. Environmental Health Department requires a soil suitability study incorporating proposed <br /> number of employees and customers, indicating that the area is suitable for septic tank usage. <br /> This must be performed prior to issuance of a building permit(s)_(San Joaquin County <br /> Development Title, Section 9-1105.2(d)). A review fee of$178.00 must be paid at time of <br /> submittal to Environmental Health Department. <br /> The sewage disposal system shall comply with the on site sewage standards of San Joaquin <br /> County prior to approval. A percolation test that meets absorption rates of the manual of <br /> septic tank practice or E.P.A. Design Manual for onsite wastewater treatment and disposal <br /> system is required for each parcel. A permit fee of$89.00 per percolation hole is required. <br /> B. State on revised site plans the maximum number of employees and customers the sewage <br /> disposal system is being designed for. In addition, show on revised plans that the leach field <br /> area will be barricaded so it cannot be driven over, parked on, or used as a storage area. This <br /> leach field area must be used for that specific purpose only,and it cannot contain any <br /> underground utility lines (San Joaquin County Development Title, Section 9-1110.4(c)(5)). <br /> C. Construction of individual sewage-disposal-system(s) under permit and inspection by the <br /> Environmental Health Department is required at the time of development based on the Soil <br /> Suitability Study findings (San Joaquin County Development Title, Section 9-1110.3 & 9- <br /> 1110.4). <br /> Page 1 of 2 <br />