Laserfiche WebLink
W <br /> s _ M K L E I N F E L D E R <br /> location are as summarized below. A copy of our field percolation test results for p-1 and P-2, <br /> along with a plan showing the approximate test hole locations, are attached. <br /> Test Number De the feet PerIc0lation:R'ate inninute/inch} <br /> P-1 3.2 125 <br /> P-2 15.6 <br /> 25 <br /> P-3 25 25 <br /> The above test results and our observations indicate that the percolation character°istics of the <br /> upper clays and silts will not meet the minimum SJCPHS percolation criteria (minimum 60 <br /> minutes/inch or faster) for on-site sewage disposal. The percolation characteristics of the <br /> underlying silty sand encountered at a depth of about 9 feet below site grade satisfies SJCPHS <br /> criteria. Accordingly, sewage ]each trenches should either extend as required into the silty sand <br /> stratum or shallow trenches connected to seepage pits that extend into the silty sand will be <br /> required. <br /> 1 <br /> This completes the scope of work requested. Our work was performed in general accordance <br /> with the standard of care that exists in San Joaquin County. No other guarantee or warranty, <br /> expressed or implied is made. If you have any questions or if we can be of further assistance, <br /> please contact our office. + <br /> Respectfully submitted, <br /> KLEINFE ER, I <br /> (J H Gu e , G. . <br /> eot hn' a] Department Manager <br /> GHG:•r <br /> Attachment <br /> 30218/ST02R412 August 23,2002 <br /> ©2002 Kleinfelder,Inc. Page 2 of 2 <br />