09/18/2002 08:46 FAX 209 9480 9003/004 <br /> KL E I N F E L D E R <br /> location are as summarized below. A copy of our field percolation test results for P-1 and P-2, <br /> along with a plan showing the approximate test dole locations, are attached. <br /> I <br /> E <br /> P-1 3.2 125 <br /> P-2 9.5 15.6 <br /> P-3 25 25 <br /> The above test results and our observations indicate that the percolation characteristics of the <br /> upper clays and silts will not meet the rainimum SJCPHS percolation criteria, (minimum 60 <br /> minutes/inch or faster) for on-site sewage disposal. The percolation characteristics. of the <br /> underlying silty sand encountered at a depth of about 9 feet below site grade satisfies SJCPHS <br /> criteria. Accordingly, sewage leach trenches should either extend as required into the silty scud <br /> stratum or shallow trenches connected to seepage pits that extend into the silty sand will be <br /> required. <br /> This completes the scope of work requested. Our work was performed in general accordance <br /> with the standard of cage that exists in San Joaquin County. No other guarantee or warranty, <br /> expressed or implied is made. If you have any questions or if we can be of further assistance, <br /> please contact our office. <br /> Respectfully submitted, <br /> pp.4FES51prV <br /> �a G <br /> HLE E <br /> Nu. 2283 <br /> G.E. <br /> eo cal Department 6 tF <br /> GH :k <br /> Attachment <br /> 1 <br /> 20319/ST02R412 August 23,2002 <br /> 0 2002 Meinfelder,Inc. Page 2 of 2 <br /> i <br /> i <br />