My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011765 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
26783
>
2600 - Land Use Program
>
PA-1800078
>
SU0011765 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:24 AM
Creation date
9/4/2019 11:08:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0011765
PE
2666
FACILITY_NAME
PA-1800078
STREET_NUMBER
26783
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
GALT
Zip
95632-
APN
00511013
ENTERED_DATE
4/25/2018 12:00:00 AM
SITE_LOCATION
26783 N CHEROKEE LN
RECEIVED_DATE
4/23/2018 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHEROKEE\26783\PA-1800078\SU0011765\SS_NL STUDY .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r2 <br /> IV. SEPTIC SYSTEM OPERATIONAL PARAMETERS AND COMPONENTS <br /> The primary and 100%replacement areas, in addition to distances in relation to existing and future <br /> domestic well locations,must be denoted on the Site Plan and/or septic system installation permit for <br /> submittal to EHD and other possible County Departments. <br /> Future septic system operation for Parcels 2 and 4 is as follows: Effluent filters are to be installed at <br /> the septic tank outlets. Effluent will gravity flow from each septic tank, travel to a four-hole D-box <br /> and be equally distributed between perforated leachline pipes within a conventional leachfield. A 42 <br /> inch diameter seepage pit shall be installed at the end of each leachline. One hundred percent <br /> replacement areas should be easily accommodated on each Parcel due to the area of each Parcel. <br /> IV. CONCLUSIONS AND RECOMMENDATIONS <br /> NLS§ 4.1. The nitrate loading calcul ions show the resultant effluent from the project, assessed as <br /> a whole, was determined to b 6.2 pp e trogen, which is below the Federal nitrate <br /> Maximum Contaminant Level f 10 ppm itrate as nitrogen, or 45 ppm as nitrate. Each <br /> proposed Parcel taken individually finds that two of the four Parcels slightly exceed the MCL and are <br /> certainly within a margin of error. <br /> NLS§ 4.2, SSS§ 6.7. It is the policy of the EHD to monitor water wells on a Parcel where the nitrate <br /> loading calculations indicate exceedance of the MCL. It is my professional opinion that monitoring <br /> is not necessary for this project because exorbitant wastewater flows have been incorporated into the <br /> c culations as a safety factor. Secondly,the indigenous soil analytical test results demonstrate very <br /> low concentrations of subsurface soil nitrate-nitrogen caused by significant suppression of <br /> nitrification and promotion of denitrification, thus leading to low nitrate concentrations in the <br /> groundwater. Even with extensive agricultural production upgradient to the property, low nitrate <br /> concentrations are observed ink e'underlying groundwater. <br /> SSS§ 5.4, 6.8. The surface and subsurface soils obviously possess a degree of permeability <br /> because stormwater infiltrates and percolates, which was observed after a series of heavy rainfall <br /> events. Given the soils underlying the subject property show inadequate permeability, it is my <br /> professional engineering recommendation to enlarge the system to the next upgrade (i.e., a 3 <br /> bedroom house to be upgraded to a 4 bedroom system). For example, if a 3 bedroom house is to be <br /> constructed which would call for a 1200 gallon tank and a leachfield infiltration area of 1098 sf, <br /> instead install a 1600 gallon tank and an infiltration area of 1467 sf. If a four bedroom or larger home <br /> is proposed to be constructed, a 2000 gallon tank and 1812 sf shall be installed. <br /> If the lowest wastewater application rate of 0.100 gals/sf/day is applied to the infiltrative area of <br /> 1467 sf,we find that a leachfield area will manage 147 gpd. A wastewater flow of 147 gpd is a <br /> reasonably expected volume from a 3 bedroom/2 bath house. <br /> Page -10- <br /> Chesney Consulting <br />