Laserfiche WebLink
DETENTION TIME EXAMPLE: <br /> Detention,Time = 3,2O0 gal tank capacitycqpacity x 0.70 30%volume lost to sludge/scum accumulation <br /> 1.5 (Peaking factor) x 1050 gals/day(worst-case flow volume) <br /> Detention Time = 1.4 days. The minimum acceptable detention time is 1.0 day. <br /> 3S <br /> DESIGN AND OPERATIONAL SPECIFICATIONS <br /> One-2,000 gallon conventional dual compartment septic tank with comminutor pump and alarm system(existing) <br /> One- 1,200 gallon conventional single compartment septic tank (to be installed) <br /> Filtration from 2,000 gallon septic tank to 1,200 gallon pump chamber tank (EHD Requirement) <br /> The existing pump will be moved to the existing septic tank that serves the north building (ADS <br /> Delivery).' Effluent from this tank will be pumped to the existing 2,000 gallon tank next to Oliveri <br /> Cabinets., <br /> u <br /> A new duplex pump system (EHD Requirement)with an Orenco BioTube® Filter Vault will be <br /> installed in the new 1,200 pump chamber. Since the Orenco pump requirements will only allow 32 <br /> gpm, the pumps will alternatively activate back and forth. Correspondingly, one pump will dose <br /> "on-demand" approximately 100 gallons to one-half of the filter bed, and the other.pump will dose <br /> the other half of the bed. This will require two - 2 inch PVC transport lines to the filter bed. One <br /> flowmeter will be installed on one of the transport lines. The total effluent volume dosed to the filter <br /> bed can be calculated by multiplying this reading by 2. <br /> Monitoring of effluent with monitoring ports or wells within, or on the perimeter of the filter bed <br /> area. Observation tubes: 4" PVC Tee at soil/effluent interface with 4" riser extending above the <br /> soil/grass,surface by at least 1.0 foot, with a screw type cap. (EHD Requirement). <br /> As-Builts of entire system after installation(EHD Requirement) <br /> Laterals: Sch. 40 PVC 1.00" nominal diameter, 1/8" orifice directed at 12 o'clock, 4.0 ft spacing„ 50 <br /> ft long <br /> Orifice Discharge Rate: 118" with 5'residual head= 0.41 gpm <br /> 50 ft -4.0 ft = 13 orifices/lateral x 0.41 gpm/orifice= 5.3 gpm/lateral <br /> Network Discharge Rate R = 12 laterals x 5.3 gpm/lateral= 64 gpm-2 = 32 gpm for each <br /> pump. <br /> Manifold=2" Sch. 40 PVC <br /> Total Dose Volume (TDV) from both pumps: <br /> 0.041 gals/ft x 50 ft x 12 laterals=25 gals x 5 times lateral void volume= 123 gals <br /> 2" x 40 ft,manifold= 0.163 gals/ft x 40 ft=6.5 gals <br /> Transport line =2" =0.163 gals/ft x 360 ft= 59 gals <br /> 123 + 6.5 + 59 = 189 gals/dose_ 64 gpm = 3 min/dose <br /> 700 gpd (talc. on Pg. 9) - 189 gals/dose = 3.7 doses/24 hr period <br /> 14 <br /> Chesney Consulting <br />