Laserfiche WebLink
S = sufficient <br /> s I = Insufficient ° <br /> S I 6.0 PERCOLATION TEST INFORMATION SECTION <br /> ❑ 6.1 Site map showing the location,with concise and accurate dimensions of the percolation test holes an the parcel. <br /> ❑ 6.2 The minimum number of shallow and deep percolation tests was performed for each parcel. <br /> ❑" ❑ 6.3 Description of the date, time and protocol used to prepare the test hole, including depth and dimensions of hole, <br /> preparation of hole, and depth of water used to presoak(minimum 12 inches). <br /> ❑ 6.4; Description of the date,time and condition of the test hole after the 24-hour soak period (hole still intact, hole dry, <br /> depth to water remaining in hole, etc.) <br /> 121 ❑ 6.5 The test conformed to SJC Policy EHD 02-02 (correct depth, diameter,2" gravel, 6"water retial, correct readings <br /> recorded). <br /> ❑ ❑ 6.6 Complete Percolation Test Form (including readings)was provided with RENS verification signature. The rate <br /> was correctly calculated using the last reading. <br /> ❑ 6.7 Discussion of any potential problems predicted and/or the need for an engineered or alternative septic system. a <br /> I <br /> ❑ 6.8 Discussion of percolation rates in relation to the type, size and location of future leach fields needed at the site. i <br /> 7.0 CONCLUSION SECTION <br /> F-j ❑ 7.1 The report was signed and stamped by the appropriately registered individual <br /> Reviewed By: Lr/ J-0- (,{� � Reviewed Date: (, !7 oSi <br /> GRID 26-03 Page 2 of 3 Sod Suitability Checklist <br /> 7/1412003 <br />