Laserfiche WebLink
II <br /> .G <br /> File No. 20-3551.-011 ]�� KLEI NFELDER <br /> May 26, 1992 �4 <br /> Page 2 of 3 <br /> it <br /> t , <br /> I <br /> in our discussion with Mr. Bill Helms of the State Drought Center, <br /> we understand that the State uses an annual average water <br /> consumption rate of 1 acre--foot per year for a family of five. <br /> This includes alllMwater used for domestic purposes and landscape <br /> watering but excludes irrigation. This value is equal to <br /> approximately 9001 gallons per day per family and approximately <br /> 14 ,400 gallons per day for the sixteen proposed residences on an <br /> annual basis. <br /> As you can see b com arin the above figures,Y Y P g gores, domestic use from <br /> sixteen wells constructed at the site would equal approximately 20 <br /> percent of the volume used annually over the thirty-two years of <br /> irrigation at the site. However, the above values €or residential <br /> use do not include any irrigation water that may be' used on the <br /> individual lots. !IIt is our opinion that if portions of the lots <br /> are farmed; the volume of water used for irrigation and domestic <br /> purposes will still not equal the volume of water used annually <br /> during the thirty-two years of heavy irrigation. <br /> WATER TESTS <br /> As requested by Environmental Health Services personnel, on April <br /> 15, 1992 , a representative of our firm obtained samples from wells <br /> located at the ttio residences on the site. The samples were <br /> delivered to FGL Environmental laboratory in Stockton for general <br /> mineral content and PCB testing. The test results are included <br /> with this report. <br /> II <br /> CONSTRUCTION FEASIBILITY <br /> We understand that'Ithe San Joaquin County Planning Department has <br /> requested information regarding the feasibility of constructing <br /> residences on the subject site. Although our scope of services for <br /> the septic system ';�suitability study did. not include test borings <br /> for geotechnical purposes, we did drill several test holes for <br /> percolation testing. The materials encountered in the per <br /> test holes were consistent with materials typically encountered in <br /> the site area. ;M <br /> Based on our experience with projects in the site area for which r <br /> our firm has provided geotechnical services, it, is our opinion that <br /> the sixteen proposed lots are suitable for typical residential <br /> construction. The structures can likely be supported on ' <br /> conventional spread and/or continuous foundations bearing on the <br /> existing materials' or on Engineered Fill. <br /> One possible concern in the site area is the presence of expansive F <br /> clay soils at thelCsurface. However, if expansive clay soils are <br /> present beneath a:Fproposed structure location, several methods +, <br /> exist to reduce the risk associated with constructing on expansive <br /> soils. IE <br /> II a <br /> i� <br /> Copyright 1992 Kleinfelder, Inc. <br /> I� <br />