SU0009316 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COMCONEX
>
17800
>
2600 - Land Use Program
>
PA-1200154
>
SU0009316 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:57 AM
Creation date
9/4/2019 11:29:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0009316
PE
2666
FACILITY_NAME
PA-1200154
STREET_NUMBER
17800
Direction
S
STREET_NAME
COMCONEX
STREET_TYPE
RD
City
MANTECA
Zip
95336-
APN
20818023
ENTERED_DATE
8/13/2012 12:00:00 AM
SITE_LOCATION
17800 S COMCONEX RD
RECEIVED_DATE
8/13/2012 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\COMCONEX\17800\PA-1200154\SU0009316\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 1 <br /> SOIL PROFILE CHARACTERISTICS AND <br /> ANALYTICAL TEST RESULTS <br /> SAMPLE DEPTH AND PERCOLATION SOIL SOIL NITRATE- PH AND <br /> (SAMPLE NUMBER ON RATE CLASSIFICATION NITROGEN CATION EXCHANGE <br /> TEST RESULT FORM) CONTENT CAPACITY <br /> 42"DEPTH 5.8 min/in Fine Sandy Silt 3 ppm NO,N 7.9 15.5 meq/100g <br /> 8 FT DEPTH 6.9 min/in Silty Fine Sand 2 ppm NO,N 8.2 19.9 meq/100g <br /> C. PERCOLATION TEST RESULTS <br /> SSS§6.2. To assess the permeability at prescribed depths of the on-site soils,the two <br /> aforementioned percolation test borings were completed in the locations depicted on the <br /> preliminary Site Plan found in Appendix C. <br /> SSS§ 6.3. After drilling the perc test borings, the sidewalls of the shallow boring was scored <br /> with a pry-bar to open potentially smeared sidewalls. The deep test boring could not be scored <br /> due to its depth. Two inches of fine gravel was placed at the bottom and three-inch perforated <br /> PVC pipe was inserted in each test boring. On June 25,2012, each boring was pre-saturated with <br /> 24 inches of water at 0900 hrs, 24 hrs before the start of testing. <br /> SSS§ 6.4, 6.5. On June 26,2012,percolation testing commenced. No standing water was <br /> observed after the 24-hr soak period in both of the test borings, consequently, EHD Perc Test <br /> Procedure#2 was conducted for both test borings. Testing was done over a four-hour period to <br /> induce maximum soil saturation. <br /> The test results indicat rapid ut not excessively rap'dtperc rates at the 42 inch and 96 inch depth <br /> test depths. A summary e perc test results-with corresponding application rates in gallons of <br /> effluent accepted per square foot of soil per day are illustrated in Table 2: <br /> TABLE 2 <br /> PERCOLATION TEST RESULTS WITH CORRESPONDING <br /> APPLICATION RATES IN GALLONS/FT=/DAY <br /> 42 INCH DEEP PERC TEST BORING 5.8 min/inch / 1.029 gallons/ft/day <br /> PERCOLATION RATE/APPLICATION RATE <br /> 96 INCH DEEP(8.0 FT)PERC TEST BORING 6.9 min/inch / 0.970 gallons/W/day <br /> PERCOLATION RATE/APPLICATION RATE <br /> App5cwim Rat adapted fmm Califcr Smm Water Reaa Cw of Board CWde&wsfor Me Vi) ofSe a Symm and is based m the I m Rate. <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.