My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0009316 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COMCONEX
>
17800
>
2600 - Land Use Program
>
PA-1200154
>
SU0009316 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:57 AM
Creation date
9/4/2019 11:29:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0009316
PE
2666
FACILITY_NAME
PA-1200154
STREET_NUMBER
17800
Direction
S
STREET_NAME
COMCONEX
STREET_TYPE
RD
City
MANTECA
Zip
95336-
APN
20818023
ENTERED_DATE
8/13/2012 12:00:00 AM
SITE_LOCATION
17800 S COMCONEX RD
RECEIVED_DATE
8/13/2012 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\COMCONEX\17800\PA-1200154\SU0009316\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following calculation illustrates that a 1,200 gallon septic tank will allow sufficient influent <br /> hydraulic residence time(HRT)within the septic tank and promote nitrogen decomposition. A <br /> Polylok TM PL-122 effluent filter must be installed on the outlet tee of the septic tank. <br /> Detention Time: <br /> Detention Time= 1.200 gal septic tank capacity x 0.80(20%volume lost to volume of sludge/scum accumulation) <br /> 2 (Daily Peaking factor)x 495 gals/day <br /> Detention Time=1.0 days. The minimum acceptable detention time is 1.0 day. Therefore,a 1,260 <br /> gallon septic tank is suitable for ample detention time given the extremely high ADF,and will all or <br /> greater nitrogen decomposition. f <br /> B. LEACBLINE AND FILTER BED REQUIREMENT CALCULATION BASED ON SAN <br /> JOAQUIN COUNTY SEWAGE STANDARDS FOR COMMERCIAL SEPTIC SYSTEMS: <br /> Base Tank Capacity(BTC)= 1,200 gal. Leachline Equivalent Requirement= 1,200 gallons BTC <br /> +495 ADF x 0.200 sand Soil Factor(SF)=339 lineal feet of leachline(LFLL) required. <br /> Filter Bed Requirement: <br /> 339 LFLL x 3 (sandy soils)= 1,017 sq ft. Primary disposal area designated on the Site <br /> Plans: 20 ft N-S x 50 ft E-W = 1,000 sq ft calculated filter bed disposal area. The secondary <br /> disposal area(100% Replacement Area)is also designated to be the same area at 1,000 sq ft <br /> and is proposed to be directly south of the primary area. When failure occurs, <br /> approximately ten parking stalls must be removed and the replacement disposal area <br /> installed. These 10 removed parking stalls will then be relocated to south of the entrance <br /> driveway where there are 14 proposed spaces and area for 15 additional parking stalls. <br /> Consequently, ample area exists for the 100% replacement area and for the relocation of <br /> parking stalls. <br /> The filter bed should be installed as high in elevation as possible to take advantage of <br /> evapotranspiration, consequently,the septic tank must be installed as high in elevation as possible. <br /> Therefore, influent lines from the break room sink and restrooms must come through the tops <br /> of the building footings and not under the footings. The project plumber and septic system <br /> contractor must coordinate to ensure this occurs. The Plan Dimensional View of the filter bed, <br /> as proposed, is found in Appendix A. <br /> The proposed operation of the wastewater management system is as follows: Graywater from <br /> sinks and blackwater from toilets will flow into a 1,200 gallon,two compartment septic tank. As <br /> referenced, a PolylokTM PL-122 effluent filter must be installed on the outlet tee of the septic tank. <br /> Effluent will gravity flow west to a distribution box (D-box) at the east-center of the primary filter <br /> bed. The D-box must be level and be installed with Tuff Tite® Speed LevelersTM to achieve <br /> optimum and equal effluent distribution. Equalized effluent volumes will gravity flow west into <br /> three separate perforated leachlines,which should be installed as level as possible. <br /> 10 <br />