Laserfiche WebLink
S = Sufficient <br /> 1 = Insufficient <br /> S I 6.0 PERCOLATION TEST INFORMATION SECTION <br /> ® ❑ 6.1 Site map showing the location,with concise and accurate dimensions of the percolation test holes on the parcel. <br /> ® ❑ 6.2 T1-e7'n 6mum number of shallow and deep percolation tests was performed for each parcel. <br /> ® ❑ 6.3 Description of the date, time and protocol used to prepare the test hole, including depth and dimensions of hole, <br /> preparation of hole, and depth of water used to presoak(minimum 12 inches). <br /> ® ❑ 6.4 Descrip it on of the date, time and condition of the test hole after the 24-hour soak period (hole still intact, hole dry, <br /> depth to water remaining in hole, etc.) <br /> ® ❑ 6.5 The test conformed to SJC Policy EHD 02-02(correct depth,diameter,2"gravel, 6"water refill, correct readings <br /> recorded). � <br /> ❑ 6.6 Complete Percolation Test Form (including readings)was provided with REHS verification signature. The rate <br /> was correctly calculated using the last reading. <br /> ❑ 6.7 Discussion of ahy potential problems predicted and/or the need for an engineered or alternative septic system. <br /> �f <br /> F-16.8 Discus ton of percolation rates in relation to the type, size and location of future leach fields needed at the site. <br /> 11 <br /> 7.0 CONCLUSION SECTION <br /> E2 ❑ 7.1 The report was signed and stamped by the appropriately registered individual <br /> Reviewed By: a 5 i Z w�05 - --Reviewed Date: <br /> Oil)26-02-003 Page 2 of 3 Suit Suitabilay Ch�&Iist <br />