Laserfiche WebLink
• Discussion of Percolation Test Results <br /> The soils within the percolation test areas have demonstrated satisfactory percolation <br /> rates for the use of standard septic systems utilizing leach lines and seepage pits in <br /> accordance with the requirements of the San Joaquin County Environmental Health <br /> Department. <br /> Because of the rapid percolation rates encountered, the San Joaquin County <br /> Environmental Health Department will require eight- to 20-foot separations from the <br /> bottom of the dispersal system to ground water (see Table 2). Ground water is <br /> anticipated to be encountered from 127 to 135 feet below ground surface at the Site; <br /> consequently, no modifications to standard septic systems should be required. <br /> Discussion of Septic System Sizing <br /> Future septic system construction should follow the San Joaquin County On-Site <br /> Wastewater Treatment Systems Standards (2017) where applicable. No new <br /> construction is anticipated. <br /> • <br /> • <br /> LOGE 1845 Page 8 <br />