My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0009728 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORD
>
21411
>
2600 - Land Use Program
>
PA-1300133
>
SU0009728 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:34:11 AM
Creation date
9/4/2019 11:37:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0009728
PE
2622
FACILITY_NAME
PA-1300133
STREET_NUMBER
21411
Direction
N
STREET_NAME
CORD
STREET_TYPE
RD
City
CLEMENTS
Zip
95227-
APN
02315036 & 37
ENTERED_DATE
8/16/2013 12:00:00 AM
SITE_LOCATION
21411 N CORD RD
RECEIVED_DATE
8/16/2013 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CORD\21411\PA-1300133\SU0009728\SSS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 2. Percolation Test Summary <br /> Test No., Percolation Percolation Test Duration Comments <br /> Date Tested Test Rate (see notes) <br /> Depth (ft.) (minutes/inch) <br /> P1 (Parcel 1) Satisfactory <br /> 10/15/13 3.20 11.9 4 hrs. <br /> Shallow Test perc. rate <br /> P2 (Parcel 2) Satisfactory <br /> 10/15/13 3.15 10.4 4 hrs. perc. rate <br /> Shallow Test <br /> P3 (Parcel 3) Satisfactory <br /> 10/15/13 3.35 3.6 4 hrs. <br /> Shallow Test perc. rate Ir/ <br /> P4 (Parcel 4) <br /> 10/15/13 3.21 4.2 4 hrs. Satisfactory <br /> Shallow Test perc. rate <br /> Note: A satisfactory percolation rate for a "shallow- test is less than or equal to 60 minutes per inch. A satisfactory <br /> percolation rate for a "deep"test is less than or equal to 30 minutes per inch. <br /> Discussion of Percolation Test Results <br /> The soils within the percolation test areas have demonstrated satisfactory percolation <br /> rates for the use of standard septic systems in accordance with the requirements of the <br /> San Joaquin County Environmental Health Department. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines and seepage pits should follow the San <br /> Joaquin County On-Site Wastewater Disposal Standards (2003) where applicable. <br /> LOGE 1323 Page 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.