My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
8111
>
3500 - Local Oversight Program
>
PR0544804
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:20:01 AM
Creation date
9/4/2019 1:30:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
WORK PLANS
RECORD_ID
PR0544804
PE
3528
FACILITY_ID
FA0003850
FACILITY_NAME
M&M BUILDERS SUPPLY INC
STREET_NUMBER
8111
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95304
APN
25014006
CURRENT_STATUS
02
SITE_LOCATION
8111 W ELEVENTH ST
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
yl' . <br /> -Wright Environmental Services, Inc. <br /> 'i <br /> Monitoring Well Construction <br /> 1. The proper permits will be obtained from thei appropriate agency or water <br /> district, scheduling a Well Inspector as required to be present to witness the <br /> installation of the annular seal. Soil borings will be drilled with a continuous-flight <br /> hollow-stem auger of nominal 8 inches outside diameter (to leave 2-inch annular <br /> space for well construction). All augers will be thoroughly steam-cleaned prior to <br /> arriving at the site. The augers will be steamed cleaned between borings at a location <br /> well away from the proposed borings or adequate clean auger will be available to <br /> complete all of the wells without reusing auger sections. <br /> l <br /> 2. The borings will be advanced to the uppermost ifwater bearing zone (or a depth <br /> of 45 feet if a saturated zone is not encountered and in absence of other exploration <br /> depth specifications). If a saturated zone is encountered , the boring will advance no <br /> further than 15 feet below first encountered groundwater or 5 feet into the <br /> underlying clay aquitard. If entered, a seal will be placed in the overdrilled portion i <br /> of the aquitard. it <br /> 3. During the drilling operations, 55-gallon drums will be on site to contain <br /> potentially contaminated soils, drilling muck and rinse water to minimize surface <br /> contamination. <br /> 4. Where borings are completed as groundwater monitoring wells, 2-inch ID <br /> schedule 40 PVC blank pipe will be used. Well screen selection will be 2 inch ID <br /> Schedule 40 PVC pipe with 0.020 inch machine slot (in absence of other <br /> specifications). Sections will be threaded and screwed flush together; glues will not <br /> be used. Screens will extend 3-5 feet above first encountered groundwater. The <br /> annulus of the perforated section will be packed with{',clean #3 or #4 Monterey Sand, <br /> Lonestar 2/12 Sand or equivalent, to a level about 2-feet above the screen interval <br /> (field experience has shown this monitoring well design has worked well in <br /> stratified alluvial and fine grained environments; if l'special well designs supersede <br /> this design, a specification will be attached). " <br /> Final well design will be adjusted in the field to siteE specific subsurface conditions <br /> observed in the borehole, and well screens or slofs will be placed so as not to <br /> interconnect two possible aquifers or uncontaminated vadose zone strata. Screens <br /> will extend a nominal length (up to 5 feet) above` first encountered unconfined <br /> groundwater for floating product detection where needed. A 1-2 foot thick bentonite <br />'r seal will be placed on top of the sandpack. A cement grout annular seal which <br /> extends to the surface will be placed by tremie line ;from the bottom to top of the <br /> remaining annular space above the bentonite. Sealing can be modified as regulatory <br /> input requires. <br /> 5. The top of the well casing will be locked do prevent contamination and <br /> f tampering. An above-grade or at-grade well completion will depend upon well <br /> location. At-grade completions require traffic rated boxed set in concrete or cement <br /> grout just above grade. Above-grade completion will require a 6-inch diameter <br /> locking, steel protective "stovepipe" casing and a Cli 'sty, or equivalent, traffic box <br /> and concrete pad and surface poles or barriers to mark the location. <br /> WES Sampling Protocols last rev. 5/96 Page 4 <br /> i <br /> i <br /> r <br /> li <br />