i <br /> . rz� <br /> i LABORATORY NARRATIVE <br /> 1, Modified TO-3 <br /> ! 1 Geological Technics <br /> Workorder#0301024 <br /> Two i Liter Tedlar Bag samples were received on January 03, 2003. The laboratory performed analysis via <br /> modified EPA Method TO-3 for Methyl tert-Butyl Ether(MTBE),Benzene, Toluene,Ethylbenzene, Xylenes <br /> and Total Petroleum Hydrocarbons (TPH). MTBE/BTEX was analyzed via GC/PID and TPH via GC/FID. . <br /> The TPH results are calculated using the response of Gasoline. A molecular weight of 100 is used to convert <br /> the TPH ppmv result to ueL. The method involves concentrating up to 200 mL .of sample. The <br /> } concentrated aliquot is then dry purged to remove water vapor prior to entering the chromatographic system. <br /> See the data sheets for the reporting limits for each compound. <br /> Requirement TD-3 ATL Modlrcations <br /> Daily Calibration Standard Prior to sample analysis Prior to sample analysis(BTEX and TPH.stds.)and after the <br /> Frequency and every 4-6 hrs analytical batch</=20 samples(BTEX std.) <br /> Initial Calibration Calculation 4-point calibration 5-point calibration using average-Response Factor <br /> using a linear <br /> regression mode] <br /> Initial Calibration Frequency Weekly When daily calibration standard recovery is outside 75 <br /> or upon significant changes to procedure or <br /> instrumentation <br /> Moisture Control Nafion system Sorbent system <br /> _ Minimum Detection Limit(MDL) Calculated using the 40 CFR Pt. 136 App. B <br /> equation DL=A+3.3S, <br /> where A is.intercept of <br /> calibration line and S is <br /> the standard deviation <br /> of at least 3 reps of low <br /> level standard <br /> ( Preparation of Standards Levels achieved- Levels achieved through loading various volumes of the <br /> Lthrough dilution of gas gas mixture <br /> mixture <br /> Receiving Notes r <br /> There were no receiving discrepancies. <br /> L Analytical Notes <br /> There were no analytical discrepancies. <br /> Definition of Data Oualifying Flats <br /> Seven qualifiers may have been used on the data analysis sheets and.indicate as follows: <br /> B - Compound present in laboratory blank greater than repotting limit.. <br /> J - Estimated value. <br /> E- Exceeds instrument calibration range. <br /> . S - Saturated peak. <br /> 1 � P _ - <br /> Q - Exceeds quality control limits. <br /> U- Compound analyzed for but not detected above the detection limit. - <br /> M- Reported value may be biased due to apparent matrix interferences: <br /> Page 2 of 8 <br />